HEAL DSpace

Isopachic patterns by the moiré method - Highly satisfactory correlation is found between results obtained with proposed method and those obtained by other experimental methods

DSpace/Manakin Repository

Show simple item record

dc.contributor.author Theocaris, PS en
dc.date.accessioned 2014-03-01T01:37:39Z
dc.date.available 2014-03-01T01:37:39Z
dc.date.issued 1964 en
dc.identifier.issn 00144851 en
dc.identifier.uri http://hdl.handle.net/123456789/21599
dc.title Isopachic patterns by the moiré method - Highly satisfactory correlation is found between results obtained with proposed method and those obtained by other experimental methods en
heal.type journalArticle en
heal.identifier.primary 10.1007/BF02329632 en
heal.identifier.secondary http://dx.doi.org/10.1007/BF02329632 en
heal.publicationDate 1964 en
heal.abstract Interference between a grating, with line rulings of a density of 500 lines/in., and its shadow is used for the determination of isopachics in plane-stress problems. The procedure consists in using a white collimated light beam obliquely incident to the model. A reference master grating is attached to the surface of the model and the interference pattern of this grating and its shadow, produced by the oblique light beam, is photographed in a position normal to the model. Interference patterns before and after loading of the specimen allow the determination of isopachics. © 1964 Society for Experimental Mechanics, Inc. en
heal.publisher Kluwer Academic Publishers en
heal.journalName Experimental Mechanics en
dc.identifier.doi 10.1007/BF02329632 en
dc.identifier.volume 4 en
dc.identifier.issue 6 en
dc.identifier.spage 153 en
dc.identifier.epage 159 en