HEAL DSpace

On the calibration of position sensors based on magnetic delay lines

DSpace/Manakin Repository

Show simple item record

dc.contributor.author Hristoforou, E en
dc.contributor.author Chiriac, H en
dc.contributor.author Neagu, M en
dc.contributor.author Karayannis, V en
dc.date.accessioned 2014-03-01T01:45:42Z
dc.date.available 2014-03-01T01:45:42Z
dc.date.issued 1997 en
dc.identifier.uri http://hdl.handle.net/123456789/24692
dc.subject Industrial Application en
dc.subject Magnetic Field en
dc.subject Domain Wall en
dc.title On the calibration of position sensors based on magnetic delay lines en
heal.type journalArticle en
heal.identifier.primary 10.1016/S0924-4247(97)80153-7 en
heal.identifier.secondary http://dx.doi.org/10.1016/S0924-4247(97)80153-7 en
heal.publicationDate 1997 en
heal.abstract Results on the characteristics of three position sensors based on magnetic delay line techniques are illustrated in this paper. These sensors are based on the linear motion of coils or magnets along the length of a magnetic delay line. The uncertainty of the first sensor has been improved up to 40 μm m−1 by applying bias field along its length, en
heal.journalName Sensors and Actuators A-physical en
dc.identifier.doi 10.1016/S0924-4247(97)80153-7 en


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record