dc.contributor.author |
Hristoforou, E |
en |
dc.contributor.author |
Reilly, R |
en |
dc.date.accessioned |
2014-03-01T01:08:02Z |
|
dc.date.available |
2014-03-01T01:08:02Z |
|
dc.date.issued |
1990 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/10254 |
|
dc.subject |
Frequency Response |
en |
dc.subject |
Mechanical Stress |
en |
dc.subject |
Spatial Resolution |
en |
dc.subject |
Strain Gauge |
en |
dc.title |
New mechanical stress transducers based on amorphous alloys |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1109/20.104447 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1109/20.104447 |
en |
heal.publicationDate |
1990 |
en |
heal.abstract |
Novel stress transducers of simple construction are described, which can easily be formed into arrays with a great reduction in interconnections relative to discrete strain gauges. Their frequency response extends to DC, and the arrays lend themselves to measuring distribution of pressure or shear at interfaces between contacting surfaces. The principle of operation is based mainly on the properties of |