HEAL DSpace

Comparison of inductively coupled plasma mass spectrometry with inductively coupled plasma atomic emission spectrometry and instrumental neutron activation analysis for the determination of rare earth elements in Greek bauxites

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Ochsenkuhn-Petropoulou, M en
dc.contributor.author Ochsenkuhn, K en
dc.contributor.author Luck, J en
dc.date.accessioned 2014-03-01T01:08:17Z
dc.date.available 2014-03-01T01:08:17Z
dc.date.issued 1991 en
dc.identifier.issn 0584-8547 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/10392
dc.subject Inductive Coupled Plasma en
dc.subject inductively coupled plasma mass spectrometry en
dc.subject Rare Earth Element en
dc.subject Instrumental Neutron Activation Analysis en
dc.subject.classification Spectroscopy en
dc.subject.other GEOLOGICAL-MATERIALS en
dc.subject.other SAMPLES en
dc.title Comparison of inductively coupled plasma mass spectrometry with inductively coupled plasma atomic emission spectrometry and instrumental neutron activation analysis for the determination of rare earth elements in Greek bauxites en
heal.type journalArticle en
heal.identifier.primary 10.1016/0584-8547(91)80006-O en
heal.identifier.secondary http://dx.doi.org/10.1016/0584-8547(91)80006-O en
heal.language English en
heal.publicationDate 1991 en
heal.abstract For the determination of rare earth elements (REE) in bauxitic materials the techniques of inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and instrumental neutron activation analysis (IN AA) were compared. In the NIST (National Institute of Standards and Technology) bauxites SRM 697 Dominican, and SRM 69 b Arkansas, the concentration of some REEs were determined. With the reference bauxite BX-N of the ARNT (Association Nationale de la Recherche Technique) the precision and acccuracy of ICP-AES for the determination of REEs in bauxites was tested. Furthermore, Greek bauxites of the Parnassos-Gióna area were investigated. In a comparison of the three methods it was possible to calculate from the data series the precision of each method, which showed that the tendency found in the deviations for the different REEs is in acccordance with published values. Also the limits of detection for REEs in bauxites were calculated and found to be in the same range of those in the literature. © 1991. en
heal.publisher PERGAMON-ELSEVIER SCIENCE LTD en
heal.journalName Spectrochimica Acta Part B: Atomic Spectroscopy en
dc.identifier.doi 10.1016/0584-8547(91)80006-O en
dc.identifier.isi ISI:A1991EQ34200005 en
dc.identifier.volume 46 en
dc.identifier.issue 1 en
dc.identifier.spage 51 en
dc.identifier.epage 65 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής