HEAL DSpace

Practical aspects for the use of plasma emission monitoring in reactive magnetron sputtering processes

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Tsiogas, C en
dc.contributor.author Avaritsiotis, J en
dc.contributor.author Kagarakis, C en
dc.date.accessioned 2014-03-01T01:10:07Z
dc.date.available 2014-03-01T01:10:07Z
dc.date.issued 1994 en
dc.identifier.issn 0042-207X en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/11319
dc.subject Magnetron Sputtering en
dc.subject.classification Materials Science, Multidisciplinary en
dc.subject.classification Physics, Applied en
dc.subject.other Control systems en
dc.subject.other Light emission en
dc.subject.other Monitoring en
dc.subject.other Oxygen en
dc.subject.other Plasma diagnostics en
dc.subject.other Thin films en
dc.subject.other Cathode voltage en
dc.subject.other Indium oxide thin films en
dc.subject.other Oxygen flows en
dc.subject.other Plasma emission monitoring (PEM) en
dc.subject.other Reactive magnetron sputtering en
dc.subject.other Target oxidation en
dc.subject.other Tin oxide thin films en
dc.subject.other Magnetron sputtering en
dc.title Practical aspects for the use of plasma emission monitoring in reactive magnetron sputtering processes en
heal.type journalArticle en
heal.identifier.primary 10.1016/0042-207X(94)90078-7 en
heal.identifier.secondary http://dx.doi.org/10.1016/0042-207X(94)90078-7 en
heal.language English en
heal.publicationDate 1994 en
heal.abstract The sensitivity of Plasma Emission Monitoring (PEM) depends on both target material and oxygen mass flow at least for indium and tin target. Optical emission intensity and cathode voltage were recorded for several argon and oxygen flows in various tin and indium oxide thin film fabrication experiments, with the magnetron working in constant current mode. The results obtained indicate marked differences between indium and tin targets, as far as their reactive sputtering behaviour is concerned. A theoretical explanation is proposed for the observed target voltage variations with increasing oxygen mass flow in relation to the corresponding optical emission intensities. © 1994. en
heal.publisher PERGAMON-ELSEVIER SCIENCE LTD en
heal.journalName Vacuum en
dc.identifier.doi 10.1016/0042-207X(94)90078-7 en
dc.identifier.isi ISI:A1994PU78200004 en
dc.identifier.volume 45 en