HEAL DSpace

Separation and determination of gold from iron rich matrices by an off/on-line preconcentration system coupled to ICP-AES

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Ochsenkuhn-Petropulu, M en
dc.contributor.author Schramel, P en
dc.date.accessioned 2014-03-01T01:11:28Z
dc.date.available 2014-03-01T01:11:28Z
dc.date.issued 1995 en
dc.identifier.issn 0026-3672 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/11655
dc.subject coupling to ICP-spectrometer en
dc.subject iron rich matrices en
dc.subject off/on-line preconcentration en
dc.subject separation of gold en
dc.subject standard reference materials en
dc.subject.classification Chemistry, Analytical en
dc.subject.other ATOMIC-ABSORPTION SPECTROMETRY en
dc.subject.other PLASMA-MASS SPECTROMETRY en
dc.subject.other ONLINE PRECONCENTRATION en
dc.subject.other SEA-WATER en
dc.subject.other SAMPLES en
dc.subject.other EXTRACTION en
dc.subject.other ORE en
dc.title Separation and determination of gold from iron rich matrices by an off/on-line preconcentration system coupled to ICP-AES en
heal.type journalArticle en
heal.identifier.primary 10.1007/BF01244006 en
heal.identifier.secondary http://dx.doi.org/10.1007/BF01244006 en
heal.language English en
heal.publicationDate 1995 en
heal.abstract A preconcentration/separation method has been developed for the off/on-line determination by ICP-AES of gold in complex matrices, containing iron and manganese which cause severe spectral interferences on the two most sensitive Au-lines. The available automated preconcentration apparatus was modified using as absorbent the highly selective, for precious metals, chelating anion exchanger SRAFION NMRR. From the elution of this resin with 5% thiourea a nearly quantitative recovery of gold and its separation from iron, existing in percent range in the matrix, and from manganese was obtained. The validity of the developed method was tested by the determination of gold in standard reference materials from BCR, such as sewage sludge of domestic and mainly industrial origin and in a calcareous loam soil. The preconcentration procedure was synchronized with the ICP operating parameters in order to get an optimised on-line coupling of these two systems. The described process has been successfully applied to the determination of low gold contents in dissolved iron rich sediments using for the gold prospection. © 1995 Springer-Verlag. en
heal.publisher Springer-Verlag en
heal.journalName Mikrochimica Acta en
dc.identifier.doi 10.1007/BF01244006 en
dc.identifier.isi ISI:A1995RZ15800011 en
dc.identifier.volume 119 en
dc.identifier.issue 3-4 en
dc.identifier.spage 265 en
dc.identifier.epage 276 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)