Calculation of forces on the stator end windings of turbogenerator by the tranisent quasi-3d method |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1109/20.497576 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1109/20.497576 |
en |
heal.language |
English |
en |
heal.publicationDate |
1996 |
en |
heal.abstract |
Lorentz formula is applied here to calculate the electromagnetic forces acting on the stator end windings of a turbogenerator within the first several periods after it is suddenly short circuited, based on the magnetic field computed by the transient quasi-3D method (TQM). The principle of TQM and its essence-processing of winding currents-have been disussed. In the example, the forces acting on the stator end windings of a 35MW turbogenerator have been computed, when it is under no-load three phase, no-load line-to-line and noload line-to-neutral sudden short circuit conditions. Some useful results are obtained. © 1956 IEEE. |
en |
heal.publisher |
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
en |
heal.journalName |
IEEE Transactions on Magnetics |
en |
dc.identifier.doi |
10.1109/20.497576 |
en |
dc.identifier.isi |
ISI:A1996UL32000260 |
en |
dc.identifier.volume |
32 |
en |
dc.identifier.issue |
3 PART 2 |
en |
dc.identifier.spage |
1669 |
en |
dc.identifier.epage |
1672 |
en |