HEAL DSpace

Effect of surface catalysts on the long-term performance of reactively sputtered tin and indium oxide gas sensors

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Papadopoulos, CA en
dc.contributor.author Vlachos, DS en
dc.contributor.author Avaritsiotis, JN en
dc.date.accessioned 2014-03-01T01:12:48Z
dc.date.available 2014-03-01T01:12:48Z
dc.date.issued 1997 en
dc.identifier.issn 0925-4005 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/12250
dc.subject Gas classification en
dc.subject Metal oxide gas sensors en
dc.subject Sensor degradation en
dc.subject Sensor selectivity en
dc.subject Surface catalysts en
dc.subject.classification Chemistry, Analytical en
dc.subject.classification Electrochemistry en
dc.subject.classification Instruments & Instrumentation en
dc.subject.other Catalysts en
dc.subject.other Indium compounds en
dc.subject.other Oxides en
dc.subject.other Palladium compounds en
dc.subject.other Platinum compounds en
dc.subject.other Tin compounds en
dc.subject.other Metal oxide gas sensors en
dc.subject.other Chemical sensors en
dc.title Effect of surface catalysts on the long-term performance of reactively sputtered tin and indium oxide gas sensors en
heal.type journalArticle en
heal.identifier.primary 10.1016/S0925-4005(97)00190-1 en
heal.identifier.secondary http://dx.doi.org/10.1016/S0925-4005(97)00190-1 en
heal.language English en
heal.publicationDate 1997 en
heal.abstract Long term performance of tin and indium oxide thin films with palladium and platinum deposited on their surface as catalysts was studied using a standardization method proposed recently by other researchers. A simple gas classification algorithm was used to investigate the validity of the standardization method proposed and to study the effect of doping type and thickness onto the surface of SnOx and InOx films on their selectivity and stability characteristics. It was found that: (a) the proposed method is reliable for the assessment of sensor degradation; and (b) sensors with relatively thick additive layer are more reliable. (C) 1997 Elsevier Science S.A. en
heal.publisher ELSEVIER SCIENCE SA LAUSANNE en
heal.journalName Sensors and Actuators, B: Chemical en
dc.identifier.doi 10.1016/S0925-4005(97)00190-1 en
dc.identifier.isi ISI:A1997YB86800004 en
dc.identifier.volume 42 en
dc.identifier.issue 2 en
dc.identifier.spage 95 en
dc.identifier.epage 101 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής