HEAL DSpace

The stability of tin and indium oxide thin film gas sensors

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Papadopoulos, CA en
dc.contributor.author Vlachos, DS en
dc.contributor.author Avaritsiotis, JN en
dc.date.accessioned 2014-03-01T01:13:28Z
dc.date.available 2014-03-01T01:13:28Z
dc.date.issued 1997 en
dc.identifier.issn 0914-4935 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/12487
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-20544449745&partnerID=40&md5=d864f2111f00e5d21f7ca41e3561ebde en
dc.subject Gas classification en
dc.subject Metal oxide thin film gas sensors en
dc.subject Noble metal additives en
dc.subject Sensor degradation en
dc.subject Sensor selectivity en
dc.subject.classification Instruments & Instrumentation en
dc.subject.classification Materials Science, Multidisciplinary en
dc.subject.other SURFACE en
dc.title The stability of tin and indium oxide thin film gas sensors en
heal.type journalArticle en
heal.language English en
heal.publicationDate 1997 en
heal.abstract Tin and indium oxide reactively sputtered thin films, surface doped with palladium and platinum, are evaluated as sensors for carbon monoxide, methane, propane, n-butane and ethanol. The sensors are subjected to continuous heating to 450 degrees C - cooling to 150 degrees C cycles, in order to determine their degradation with continuous use. A simple nonparametric technique is used in order to determine the stability, interdependence and selectivity of the sensors. Useful results are obtained concerning the stability of sensors with different sensing layers and different catalysts deposited onto their surfaces. Sensors with different thicknesses of the same additive are found to be strongly correlated (i.e., they exhibit similar responses to the same test gases at the same temperatures; this is often referred to as collinearity in the sense that the response vector of one sensor can be derived from the response vector of another sensor by simply multiplying with a constant), while those with different additives are found to be uncorrelated. Finally, platinum-doped sensors were found to be selective, i.e., to exhibit different responses in the presence of different gases, while undoped or palladium-doped ones were found to be nonselective. Such results derived from simple techniques can be used to evaluate sensors incorporated in a multisensor pattern recognition array. en
heal.publisher MYU K K en
heal.journalName Sensors and Materials en
dc.identifier.isi ISI:A1997XY82200002 en
dc.identifier.volume 9 en
dc.identifier.issue 5 en
dc.identifier.spage 279 en
dc.identifier.epage 296 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής