HEAL DSpace

Wind energy exploitation for reverse osmosis desalination plants

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kiranoudis, CT en
dc.contributor.author Voros, NG en
dc.contributor.author Maroulis, ZB en
dc.date.accessioned 2014-03-01T01:13:30Z
dc.date.available 2014-03-01T01:13:30Z
dc.date.issued 1997 en
dc.identifier.issn 0011-9164 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/12519
dc.subject Design en
dc.subject Membranes en
dc.subject Operational performance en
dc.subject Wind turbines en
dc.subject.classification Engineering, Chemical en
dc.subject.classification Water Resources en
dc.subject.other Desalination en
dc.subject.other Design en
dc.subject.other Industrial applications en
dc.subject.other Performance en
dc.subject.other Reverse osmosis en
dc.subject.other Wind power en
dc.subject.other Wind turbines en
dc.subject.other Reverse osmosis desalination plants en
dc.subject.other Wind energy exploitation en
dc.subject.other Membranes en
dc.subject.other desalination en
dc.subject.other reverse osmosis en
dc.subject.other wind power en
dc.title Wind energy exploitation for reverse osmosis desalination plants en
heal.type journalArticle en
heal.identifier.primary 10.1016/S0011-9164(97)00065-9 en
heal.identifier.secondary http://dx.doi.org/10.1016/S0011-9164(97)00065-9 en
heal.language English en
heal.publicationDate 1997 en
heal.abstract Wind power exploitation for assisting operation of reverse osmosis desalination plants was investigated. Two problems have been analyzed: the design determining optimum plant size with respect to membrane and turbine type for different production capacity levels and various site characteristics. Operational aspects of already installed wind-powered desalination plants with respect to plant capacity and regional wind field were studied. The methodology was applied for different types of membranes, wind turbines and feed characteristics (brackish water and seawater). Generalized design curves were produced for process structural and operational variables, and the effect of secondary plant parameters was also studied. en
heal.publisher ELSEVIER SCIENCE BV en
heal.journalName Desalination en
dc.identifier.doi 10.1016/S0011-9164(97)00065-9 en
dc.identifier.isi ISI:A1997WZ11400009 en
dc.identifier.volume 109 en
dc.identifier.issue 2 en
dc.identifier.spage 195 en
dc.identifier.epage 209 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής