HEAL DSpace

A theoretical procedure for using multiple response time - Temperature integrators for the design and evaluation of thermal processes

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Stoforos, NG en
dc.contributor.author Taoukis, PS en
dc.date.accessioned 2014-03-01T01:13:33Z
dc.date.available 2014-03-01T01:13:33Z
dc.date.issued 1998 en
dc.identifier.issn 0956-7135 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/12556
dc.subject Multiple component TTI en
dc.subject Multiple response TTI en
dc.subject Sterilisation en
dc.subject Thermal processing en
dc.subject Time - Temperature integrators en
dc.subject TTI en
dc.subject.classification Food Science & Technology en
dc.subject.other FOOD en
dc.title A theoretical procedure for using multiple response time - Temperature integrators for the design and evaluation of thermal processes en
heal.type journalArticle en
heal.identifier.primary 10.1016/S0956-7135(98)00017-6 en
heal.identifier.secondary http://dx.doi.org/10.1016/S0956-7135(98)00017-6 en
heal.language English en
heal.publicationDate 1998 en
heal.abstract Time - temperature integrators (TTI) offer a sound alternative to in situ and physical - mathematical methods for thermal process design and evaluation. In the present work, the use of multi-component TTI systems, in cases where a single-component TTI with a particular z value is not available, was investigated. A procedure in using double or triple response TTI systems to evaluate the impact of a thermal process on a particular target heat labile substance was proposed and evaluated, based on a large number of product time - temperature profiles. Parameters to be considered in using a multi-component TTI included the z values of the TTI, in relation to the target z value, as well as the reference temperature used for the calculations. Guidelines for proper selection of the parameters involved are given. Although, generally, triple response TTIs performed better compared with double response TTIs, the results of double response TTIs were also satisfactory, and for practical applications, the use of a double response TTI might be sufficient. © 1998 Elsevier Science Ltd. All rights reserved. en
heal.publisher ELSEVIER SCI LTD en
heal.journalName Food Control en
dc.identifier.doi 10.1016/S0956-7135(98)00017-6 en
dc.identifier.isi ISI:000076219300004 en
dc.identifier.volume 9 en
dc.identifier.issue 5 en
dc.identifier.spage 279 en
dc.identifier.epage 287 en