dc.contributor.author |
Marinakis, GN |
en |
dc.contributor.author |
Barbenel, JC |
en |
dc.contributor.author |
Fisher, AC |
en |
dc.contributor.author |
Tsangaris, SG |
en |
dc.date.accessioned |
2014-03-01T01:14:20Z |
|
dc.date.available |
2014-03-01T01:14:20Z |
|
dc.date.issued |
1999 |
en |
dc.identifier.issn |
0006-355X |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/12999 |
|
dc.relation.uri |
http://www.scopus.com/inward/record.url?eid=2-s2.0-0033401682&partnerID=40&md5=7118646bd213ade729ed456cb3b6dc29 |
en |
dc.subject |
Capillary |
en |
dc.subject |
Power law |
en |
dc.subject |
Viscometer |
en |
dc.subject |
Viscosity |
en |
dc.subject |
Whole blood |
en |
dc.subject.classification |
Biophysics |
en |
dc.subject.classification |
Engineering, Biomedical |
en |
dc.subject.classification |
Hematology |
en |
dc.subject.other |
article |
en |
dc.subject.other |
blood viscosity |
en |
dc.subject.other |
calculation |
en |
dc.subject.other |
capillary |
en |
dc.subject.other |
infrared radiation |
en |
dc.subject.other |
sensor |
en |
dc.subject.other |
shear stress |
en |
dc.subject.other |
viscometer |
en |
dc.subject.other |
viscometry |
en |
dc.subject.other |
Blood Viscosity |
en |
dc.subject.other |
Evaluation Studies |
en |
dc.subject.other |
Hematologic Tests |
en |
dc.subject.other |
Humans |
en |
dc.subject.other |
Stress, Mechanical |
en |
dc.subject.other |
Time Factors |
en |
dc.title |
A new capillary viscometer for whole blood viscosimetry |
en |
heal.type |
journalArticle |
en |
heal.language |
English |
en |
heal.publicationDate |
1999 |
en |
heal.abstract |
A new capillary system was developed, incorporating infrared sensors, which allowed the determination of whole blood viscosity over a wide range of shear stresses. Flow conditions were defined by the geometry of the capillary and the sample pressure head. Whole blood was considered to be a power law fluid and a modified Mooney's formula was used for the calculation of the related invariants. The new viscometer proved to be very simple in use, requiring one run, had a short measuring time and utilised a small test sample volume. However it can be used for whole blood viscosity measurements only at medium and high shear stresses. |
en |
heal.publisher |
IOS PRESS |
en |
heal.journalName |
Biorheology |
en |
dc.identifier.isi |
ISI:000084907500003 |
en |
dc.identifier.volume |
36 |
en |
dc.identifier.issue |
4 |
en |
dc.identifier.spage |
311 |
en |
dc.identifier.epage |
318 |
en |