HEAL DSpace

Development of a multiple linear regression model for predicting the 28-day compressive strength of Portland pozzolan cement

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kostogloudis, GCh en
dc.contributor.author Anagnostou, J en
dc.contributor.author Ftikos, Ch en
dc.contributor.author Marinos, J en
dc.date.accessioned 2014-03-01T01:14:31Z
dc.date.available 2014-03-01T01:14:31Z
dc.date.issued 1999 en
dc.identifier.issn 0025-5432 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/13116
dc.subject Analysis of Variance en
dc.subject Compressive Strength en
dc.subject Confidence Interval en
dc.subject Hydrothermal Treatment en
dc.subject Multiple Linear Regression en
dc.subject Multiple Regression Model en
dc.subject Statistical Test en
dc.subject Sum of Squares en
dc.subject.classification Construction & Building Technology en
dc.subject.classification Engineering, Civil en
dc.subject.classification Materials Science, Multidisciplinary en
dc.subject.other Compressive strength en
dc.subject.other Mathematical models en
dc.subject.other Pozzolan en
dc.subject.other Regression analysis en
dc.subject.other Statistical tests en
dc.subject.other Portland pozzolan cement en
dc.subject.other Portland cement en
dc.title Development of a multiple linear regression model for predicting the 28-day compressive strength of Portland pozzolan cement en
heal.type journalArticle en
heal.identifier.primary 10.1007/BF02479435 en
heal.identifier.secondary http://dx.doi.org/10.1007/BF02479435 en
heal.language English en
heal.publicationDate 1999 en
heal.abstract A multiple linear regression model was developed for the prediction of the 28-day compressive strength of Portland Pozzolan Cement (PPC) containing Santorin Earth as an admixture. The independent variables of the model were: (1) the compressive strength at the age of 2 days, (2) the compressive strength after autoclave hydrothermal treatment at 2.07 N/mm(2) (300 psi) and 214 degrees C for 3 h, (3) the C3S/C2S ratio of the clinker, (4) the insoluble residue of the cement, (5) the pozzolanic activity factor and (6) the C(3)A content of the clinker. The evaluation of the proposed model was performed by various statistical tests, all of which were successful. These tests included: multiple correlation, test of the significance of coefficients (t-test), estimation of confidence intervals for coefficients, test for outliers and unusual residuals, test for influential points, conditional sums of squares, R-squared and analysis of variance. There was very good agreement between the strength predicted by the multiple regression model and experimental results. en
heal.publisher R I L E M Publications en
heal.journalName Materials and Structures/Materiaux et Constructions en
dc.identifier.doi 10.1007/BF02479435 en
dc.identifier.isi ISI:000079107700004 en
dc.identifier.volume 32 en
dc.identifier.issue 216 en
dc.identifier.spage 98 en
dc.identifier.epage 102 en


Αρχεία σε αυτό το τεκμήριο