HEAL DSpace

Oxidative induction time method based on thermogravimetry for monitoring the restabilization of post-use LDPE

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kyriakou, SA en
dc.contributor.author Statherpoulos, M en
dc.contributor.author Parissakis, GK en
dc.contributor.author Papaspyrides, CD en
dc.contributor.author Kartalis, CN en
dc.date.accessioned 2014-03-01T01:15:02Z
dc.date.available 2014-03-01T01:15:02Z
dc.date.issued 1999 en
dc.identifier.issn 0141-3910 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/13292
dc.subject oxidative induction time en
dc.subject restabilization en
dc.subject LDPE en
dc.subject.classification Polymer Science en
dc.subject.other Extrusion en
dc.subject.other Oxidation en
dc.subject.other Recycling en
dc.subject.other Remelting en
dc.subject.other Thermodynamic stability en
dc.subject.other Thermogravimetric analysis en
dc.subject.other Multiple extrusion cycles en
dc.subject.other Oxidative induction time method en
dc.subject.other Restabilization en
dc.subject.other Low density polyethylenes en
dc.title Oxidative induction time method based on thermogravimetry for monitoring the restabilization of post-use LDPE en
heal.type journalArticle en
heal.identifier.primary 10.1016/S0141-3910(99)00051-8 en
heal.identifier.secondary http://dx.doi.org/10.1016/S0141-3910(99)00051-8 en
heal.language English en
heal.publicationDate 1999 en
heal.abstract The method of oxidative induction time (OIT), based on thermogravimetry (TG), was used for monitoring the restabilization of post-use LDPE samples, subjected to multiple extrusion cycles, The method used has abilities and limitations which are discussed. The use of a restabilization system improved the oxidative stability of LDPE. A linear calibration curve correlating OIT values to the amount of restabilization system was obtained. Nevertheless, limitations concerning quantitative determinations appeared to exist, as a change in the behaviour of restabilization system during subsequent remelting cycles was observed. (C) 1999 Elsevier Science Ltd. All rights reserved. en
heal.publisher Elsevier Science Ltd, Exeter, United Kingdom en
heal.journalName Polymer Degradation and Stability en
dc.identifier.doi 10.1016/S0141-3910(99)00051-8 en
dc.identifier.isi ISI:000082364600008 en
dc.identifier.volume 66 en
dc.identifier.issue 1 en
dc.identifier.spage 49 en
dc.identifier.epage 53 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής