dc.contributor.author |
Moropoulou, A |
en |
dc.contributor.author |
Avdelidis, NP |
en |
dc.contributor.author |
Aggelakopoulou, E |
en |
dc.contributor.author |
Griniezakis, S |
en |
dc.contributor.author |
Koui, M |
en |
dc.contributor.author |
Aggelopoulos, A |
en |
dc.contributor.author |
Karmis, P |
en |
dc.contributor.author |
Uzunoglou, NK |
en |
dc.date.accessioned |
2014-03-01T01:16:34Z |
|
dc.date.available |
2014-03-01T01:16:34Z |
|
dc.date.issued |
2001 |
en |
dc.identifier.issn |
1354-2575 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/14089 |
|
dc.relation.uri |
http://www.scopus.com/inward/record.url?eid=2-s2.0-0035309037&partnerID=40&md5=02ea44e45d914491f6a92f5a77279d46 |
en |
dc.relation.uri |
http://www.scopus.com/inward/record.url?eid=2-s2.0-0035309037&partnerID=40&md5=02ea44e45d914491f6a92f5a77279d46 |
en |
dc.subject |
Ground Penetrating Radar |
en |
dc.subject |
Infrared Thermography |
en |
dc.subject |
Microwaves Reflectometry |
en |
dc.subject |
NDT |
en |
dc.subject |
Plastered Mosaics |
en |
dc.subject |
Ultrasonics |
en |
dc.subject.classification |
Instruments & Instrumentation |
en |
dc.subject.classification |
Materials Science, Characterization & Testing |
en |
dc.subject.other |
Ground penetrating radar systems |
en |
dc.subject.other |
Mortar |
en |
dc.subject.other |
Plaster |
en |
dc.subject.other |
Quality assurance |
en |
dc.subject.other |
Reflectometers |
en |
dc.subject.other |
Surface measurement |
en |
dc.subject.other |
Surface properties |
en |
dc.subject.other |
Thermography (imaging) |
en |
dc.subject.other |
Ultrasonics |
en |
dc.subject.other |
Platered mosaic surfaces |
en |
dc.subject.other |
Nondestructive examination |
en |
dc.title |
Examination of plastered mosaic surfaces using NDT techniques |
en |
heal.type |
journalArticle |
en |
heal.language |
English |
en |
heal.publicationDate |
2001 |
en |
heal.abstract |
With a view to the strict preservation regulations for mosaics and historical sites in general, only non-destructive techniques ought to be employed for significant data collection. Besides the conventional uses of non-destructive techniques, for decay diagnosis, quality assessment, and so on, information concerning plastered mosaic surfaces can be obtained from NDT techniques such as ultrasonics, ground penetrating radar, microwave reflectometry and infrared thermography. Special considerations regarding the applicability and accuracy of these techniques for this specific application are presented. The results of this laboratory research work should lead to the development of an integrated non-destructive assessment method for on site investigations on plastered mosaic surfaces. |
en |
heal.publisher |
BRITISH INST NON-DESTRUCTIVE TESTING |
en |
heal.journalName |
Insight: Non-Destructive Testing and Condition Monitoring |
en |
dc.identifier.isi |
ISI:000167971300005 |
en |
dc.identifier.volume |
43 |
en |
dc.identifier.issue |
4 |
en |
dc.identifier.spage |
241 |
en |
dc.identifier.epage |
243 |
en |