dc.contributor.author |
Chiriac, H |
en |
dc.contributor.author |
Hristoforou, E |
en |
dc.contributor.author |
Neagu, M |
en |
dc.contributor.author |
Borza, F |
en |
dc.date.accessioned |
2014-03-01T01:16:36Z |
|
dc.date.available |
2014-03-01T01:16:36Z |
|
dc.date.issued |
2001 |
en |
dc.identifier.issn |
0924-4247 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/14105 |
|
dc.subject |
Amorphous positive magnetostrictive wires |
en |
dc.subject |
Force sensors |
en |
dc.subject |
Magnetoelastic effects |
en |
dc.subject |
Magnetostrictive delay lines |
en |
dc.subject.classification |
Engineering, Electrical & Electronic |
en |
dc.subject.classification |
Instruments & Instrumentation |
en |
dc.subject.other |
Annealing |
en |
dc.subject.other |
Electric wire |
en |
dc.subject.other |
Ferromagnetic materials |
en |
dc.subject.other |
Force measurement |
en |
dc.subject.other |
Iron compounds |
en |
dc.subject.other |
Magnetic field effects |
en |
dc.subject.other |
Magnetism |
en |
dc.subject.other |
Sensors |
en |
dc.subject.other |
Amorphous positive magnetostrictive wires |
en |
dc.subject.other |
Amorphous wire |
en |
dc.subject.other |
Force sensors |
en |
dc.subject.other |
Magnetic annealing |
en |
dc.subject.other |
Magnetoelastic effects |
en |
dc.subject.other |
Magnetostrictive delay line |
en |
dc.subject.other |
Amorphous materials |
en |
dc.title |
Force measurements using Fe-rich amorphous wire as magnetostrictive delay line |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1016/S0924-4247(01)00501-5 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1016/S0924-4247(01)00501-5 |
en |
heal.language |
English |
en |
heal.publicationDate |
2001 |
en |
heal.abstract |
In this paper, we present experimental results concerning the heat treatment influence on the force response of Fe77.5Si7.5B15 amorphous wire used as magnetostrictive delay line (MDL). The amorphous wires, 125 mum diameter, were tested in the as-cast state, after stress-relief (thermally treated) and after magnetic annealing. The response of the delay line (pulsed output voltage) could be fitted by a linear curve at certain regions for the case of the as-cast amorphous wires and by an exponential curve for the case of treated wires. The sensitivity is equal to 10 mV/N, the minimum measurable change of the signal being 0.01 mV for the annealed wire corresponding to a minimum change of applied force equal to 0.001 N. (C) 2001 Elsevier Science B.V. All rights reserved. |
en |
heal.publisher |
ELSEVIER SCIENCE SA |
en |
heal.journalName |
Sensors and Actuators, A: Physical |
en |
dc.identifier.doi |
10.1016/S0924-4247(01)00501-5 |
en |
dc.identifier.isi |
ISI:000168889000054 |
en |
dc.identifier.volume |
91 |
en |
dc.identifier.issue |
1-2 |
en |
dc.identifier.spage |
223 |
en |
dc.identifier.epage |
225 |
en |