HEAL DSpace

Bow door slamming of Ro/Ro ferries

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Samuelides, M en
dc.contributor.author Servis, DP en
dc.date.accessioned 2014-03-01T01:17:35Z
dc.date.available 2014-03-01T01:17:35Z
dc.date.issued 2002 en
dc.identifier.issn 0951-8339 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/14577
dc.subject Bow doors en
dc.subject Clam doors en
dc.subject Finite elements en
dc.subject Slamming en
dc.subject.classification Engineering, Marine en
dc.subject.classification Engineering, Civil en
dc.subject.other Ferry boats en
dc.subject.other Finite element method en
dc.subject.other Loading en
dc.subject.other Slamming (ships) en
dc.subject.other Stress concentration en
dc.subject.other Structural analysis en
dc.subject.other Bow door slamming en
dc.subject.other Ocean structures en
dc.subject.other loading en
dc.subject.other passenger ship en
dc.subject.other loading en
dc.subject.other passenger ship en
dc.subject.other structural response en
dc.title Bow door slamming of Ro/Ro ferries en
heal.type journalArticle en
heal.identifier.primary 10.1016/S0951-8339(01)00025-9 en
heal.identifier.secondary http://dx.doi.org/10.1016/S0951-8339(01)00025-9 en
heal.language English en
heal.publicationDate 2002 en
heal.abstract This paper addresses the structural response of clam-type bow doors of Ro/Ro vessels under slamming loading conditions. The structural analysis is performed with the finite element code MSC/NASTRAN. The loading conditions were determined on the basis of towing tank tests, numerical calculation and regulations of classification societies, Slamming loads are applied statically and the FE code accounts for both material and geometrical nonlinearities. Apart from stress distributions, which are determined for different loading patterns, the results are used to calculate the forces and moments induced on the locking and securing elements, which secure the doors among themselves and the doors to the bow structure. The modelling methods reported may be used for the finite element analysis of similar structures. Such analyses of bow doors response under slamming loading could be submitted to classification societies for approval. (C) 2002 Elsevier Science Ltd. All rights reserved. en
heal.publisher ELSEVIER SCI LTD en
heal.journalName Marine Structures en
dc.identifier.doi 10.1016/S0951-8339(01)00025-9 en
dc.identifier.isi ISI:000176168200004 en