HEAL DSpace

Study of the effect of AC-interference on the cathodic protection of a gas pipeline

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kouloumbi, N en
dc.contributor.author Batis, G en
dc.contributor.author Kioupis, N en
dc.contributor.author Asteridis, P en
dc.date.accessioned 2014-03-01T01:18:22Z
dc.date.available 2014-03-01T01:18:22Z
dc.date.issued 2002 en
dc.identifier.issn 0003-5599 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/14966
dc.subject Cathodic protection en
dc.subject Corrosion en
dc.subject High voltage en
dc.subject Pipelines en
dc.subject.classification Metallurgy & Metallurgical Engineering en
dc.subject.other Corrosion en
dc.subject.other Electric lines en
dc.subject.other Electric potential en
dc.subject.other Electromagnetic wave interference en
dc.subject.other Gas pipelines en
dc.subject.other High-voltage power lines en
dc.subject.other Cathodic protection en
dc.subject.other cathodic protection en
dc.subject.other corrosion prevention en
dc.subject.other corrosion protection en
dc.subject.other monitoring en
dc.subject.other pipeline en
dc.title Study of the effect of AC-interference on the cathodic protection of a gas pipeline en
heal.type journalArticle en
heal.identifier.primary 10.1108/00035590210440728 en
heal.identifier.secondary http://dx.doi.org/10.1108/00035590210440728 en
heal.language English en
heal.publicationDate 2002 en
heal.abstract The aim of this fieldwork was the study of the effect of 50Hz AC, induced by high-voltage power lines, on the cathodic protection system of a natural gas pipeline. The effectiveness of cathodic protection was checked through in situ long-term monitoring and analysis of pipeline electrical parameters. The results gave an insight into the problems of the cathodic protection system operation, caused by AC interference. An AC and DC potential interdependence was observed, that previously has hardly been reported, and was scrutinized in relation to cathodically protected pipelines. The effects of the AC-interference and low frequency DC potential fluctuations, as well as the potential deviations from the protection potential, are examined. These phenomena are associated with corrosion susceptibility and difficulties in obtaining reliable cathodic protection measurements. en
heal.publisher EMERALD en
heal.journalName Anti-Corrosion Methods and Materials en
dc.identifier.doi 10.1108/00035590210440728 en
dc.identifier.isi ISI:000178652700003 en
dc.identifier.volume 49 en
dc.identifier.issue 5 en
dc.identifier.spage 335 en
dc.identifier.epage 345 en