dc.contributor.author |
Loudos, GK |
en |
dc.contributor.author |
Nikita, KS |
en |
dc.contributor.author |
Giokaris, ND |
en |
dc.contributor.author |
Styliaris, E |
en |
dc.contributor.author |
Archimandritis, SC |
en |
dc.contributor.author |
Varvarigou, AD |
en |
dc.contributor.author |
Papanicolas, CN |
en |
dc.contributor.author |
Majewski, S |
en |
dc.contributor.author |
Weisenberger, D |
en |
dc.contributor.author |
Pani, R |
en |
dc.contributor.author |
Scopinaro, F |
en |
dc.contributor.author |
Uzunoglu, NK |
en |
dc.contributor.author |
Maintas, D |
en |
dc.contributor.author |
Stefanis, K |
en |
dc.date.accessioned |
2014-03-01T01:18:30Z |
|
dc.date.available |
2014-03-01T01:18:30Z |
|
dc.date.issued |
2003 |
en |
dc.identifier.issn |
0969-8043 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/15048 |
|
dc.subject |
High resolution |
en |
dc.subject |
PSPMT |
en |
dc.subject |
Radiopharmaceutical studies |
en |
dc.subject |
Small animal imaging |
en |
dc.subject |
SPECT |
en |
dc.subject.classification |
Chemistry, Inorganic & Nuclear |
en |
dc.subject.classification |
Nuclear Science & Technology |
en |
dc.subject.classification |
Radiology, Nuclear Medicine & Medical Imaging |
en |
dc.subject.other |
Cameras |
en |
dc.subject.other |
Imaging techniques |
en |
dc.subject.other |
Photomultipliers |
en |
dc.subject.other |
Tomography |
en |
dc.subject.other |
Radiopharmaceuticals |
en |
dc.subject.other |
Gamma rays |
en |
dc.subject.other |
radiopharmaceutical agent |
en |
dc.subject.other |
animal |
en |
dc.subject.other |
article |
en |
dc.subject.other |
evaluation |
en |
dc.subject.other |
gamma radiation |
en |
dc.subject.other |
imaging system |
en |
dc.subject.other |
nonhuman |
en |
dc.subject.other |
priority journal |
en |
dc.subject.other |
scintillation camera |
en |
dc.subject.other |
three dimensional imaging |
en |
dc.subject.other |
tomography |
en |
dc.subject.other |
Algorithms |
en |
dc.subject.other |
Animals |
en |
dc.subject.other |
Bombesin |
en |
dc.subject.other |
Gamma Cameras |
en |
dc.subject.other |
Image Processing, Computer-Assisted |
en |
dc.subject.other |
Kidney |
en |
dc.subject.other |
Mice |
en |
dc.subject.other |
Mice, Nude |
en |
dc.subject.other |
Neoplasms, Experimental |
en |
dc.subject.other |
Radiopharmaceuticals |
en |
dc.subject.other |
Sensitivity and Specificity |
en |
dc.subject.other |
Signal Processing, Computer-Assisted |
en |
dc.subject.other |
Technetium |
en |
dc.title |
A 3D high-resolution gamma camera for radiopharmaceutical studies with small animals |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1016/S0969-8043(03)00025-3 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1016/S0969-8043(03)00025-3 |
en |
heal.language |
English |
en |
heal.publicationDate |
2003 |
en |
heal.abstract |
The results of studies conducted with a small field of view tomographic gamma camera based on a Position Sensitive Photomultiplier Tube are reported. The system has been used for the evaluation of radiopharmaceuticals in small animals. Phantom studies have shown a spatial resolution of 2 mm in planar and 2-3 mm in tomographic imaging. Imaging studies in mice have been carried out both in 2D and 3D. Conventional radiopharmaceuticals have been used and the results have been compared with images from a clinically used system. (C) 2003 Elsevier Science Ltd. All rights reserved. |
en |
heal.publisher |
PERGAMON-ELSEVIER SCIENCE LTD |
en |
heal.journalName |
Applied Radiation and Isotopes |
en |
dc.identifier.doi |
10.1016/S0969-8043(03)00025-3 |
en |
dc.identifier.isi |
ISI:000182420100013 |
en |
dc.identifier.volume |
58 |
en |
dc.identifier.issue |
4 |
en |
dc.identifier.spage |
501 |
en |
dc.identifier.epage |
508 |
en |