HEAL DSpace

Detection of crack nucleation in sheet metalforming by monitoring infrared radiation

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Andrianopoulos, NP en
dc.contributor.author Champidis, KT en
dc.contributor.author Iliopoulos, AP en
dc.date.accessioned 2014-03-01T01:18:51Z
dc.date.available 2014-03-01T01:18:51Z
dc.date.issued 2003 en
dc.identifier.issn 8756-758X en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/15229
dc.subject Crack nucleation en
dc.subject Infrared radiation en
dc.subject Metalforming en
dc.subject Plastic strains localisation en
dc.subject Thermoelasticity en
dc.subject.classification Engineering, Mechanical en
dc.subject.classification Materials Science, Multidisciplinary en
dc.subject.other Infrared radiation en
dc.subject.other Strain en
dc.subject.other Stretching en
dc.subject.other Temperature en
dc.subject.other Thermoelasticity en
dc.subject.other Crack nucleation en
dc.subject.other Plastic strains en
dc.subject.other Sheet metalforming en
dc.subject.other Cracks en
dc.title Detection of crack nucleation in sheet metalforming by monitoring infrared radiation en
heal.type journalArticle en
heal.identifier.primary 10.1046/j.1460-2695.2003.00521.x en
heal.identifier.secondary http://dx.doi.org/10.1046/j.1460-2695.2003.00521.x en
heal.language English en
heal.publicationDate 2003 en
heal.abstract In the present work a method is described for the early detection of large plastic strains localisation and subsequent crack nucleation in sheet metalforming. The method is based on the monitoring of the infrared radiation emitted from the material during stretching. It is concluded that the point of the final crack nucleation can be located in the very early stages of stretching, when overall mean strains are insignificant (less than 20% of the yielding strain of the material). en
heal.publisher BLACKWELL PUBLISHING LTD en
heal.journalName Fatigue and Fracture of Engineering Materials and Structures en
dc.identifier.doi 10.1046/j.1460-2695.2003.00521.x en
dc.identifier.isi ISI:000181810000005 en
dc.identifier.volume 26 en
dc.identifier.issue 4 en
dc.identifier.spage 323 en
dc.identifier.epage 328 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής