HEAL DSpace

A gas leak rate measurement system for the ATLAS MUON BIS-monitored drift tubes

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Alexopoulos, T en
dc.contributor.author Avramidou, R en
dc.contributor.author Dris, E en
dc.contributor.author Filippas, TA en
dc.contributor.author Gazis, EN en
dc.contributor.author Katsoufis, EC en
dc.contributor.author Maltezos, S en
dc.contributor.author Savva, P en
dc.contributor.author Stavropoulos, G en
dc.contributor.author Tsipolitis, G en
dc.date.accessioned 2014-03-01T01:19:45Z
dc.date.available 2014-03-01T01:19:45Z
dc.date.issued 2004 en
dc.identifier.issn 0168-9002 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/15691
dc.subject Drift tubes en
dc.subject Gas leak en
dc.subject Gass-filled muon chambers en
dc.subject Quality assurance en
dc.subject.classification Instruments & Instrumentation en
dc.subject.classification Nuclear Science & Technology en
dc.subject.classification Physics, Particles & Fields en
dc.subject.classification Spectroscopy en
dc.subject.other Gas dynamics en
dc.subject.other Leakage (fluid) en
dc.subject.other Manometers en
dc.subject.other Pressure drop en
dc.subject.other Quality assurance en
dc.subject.other Thermal insulation en
dc.subject.other Tubes (components) en
dc.subject.other Drift tubes en
dc.subject.other Gas leaks en
dc.subject.other Gas-filled muon chambers en
dc.subject.other Drift chambers en
dc.title A gas leak rate measurement system for the ATLAS MUON BIS-monitored drift tubes en
heal.type journalArticle en
heal.identifier.primary 10.1016/j.nima.2003.10.095 en
heal.identifier.secondary http://dx.doi.org/10.1016/j.nima.2003.10.095 en
heal.language English en
heal.publicationDate 2004 en
heal.abstract A low-cost and reliable system is presented which was developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDT) to be used for the Muon Spectrometer of the ATLAS experiment at LHC. In order to meet the ATLAS schedule, 100 MDTs are tested simultaneously each time by the developed setup. The method used is based on the measurement of the gas pressure drop in each MDT with respect to the pressure of a gas tight reference tube within a time. interval of 48 h and is accomplished with a differential manometer. A high degree of temperature stability and homogeneity is achieved inside two thermally insulated boxes and leads to a satisfactory accuracy for the measurement of the gas leak rates. The developed system is appropriate within the ATLAS specifications for mass production. More than 18500 MDTs have been tested up to now and the obtained results are presented. (C) 2003 Elsevier B.V. All rights reserved. en
heal.publisher ELSEVIER SCIENCE BV en
heal.journalName Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment en
dc.identifier.doi 10.1016/j.nima.2003.10.095 en
dc.identifier.isi ISI:000220607100006 en
dc.identifier.volume 521 en
dc.identifier.issue 2-3 en
dc.identifier.spage 332 en
dc.identifier.epage 342 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)