HEAL DSpace

Influence of large-scale installation of energy saving lamps on the line voltage distortion of a weak network supplied by photovoltaic station

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Korovesis, PN en
dc.contributor.author Vokas, GA en
dc.contributor.author Gonos, IF en
dc.contributor.author Topalis, FV en
dc.date.accessioned 2014-03-01T01:20:38Z
dc.date.available 2014-03-01T01:20:38Z
dc.date.issued 2004 en
dc.identifier.issn 0885-8977 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/15995
dc.subject fluorescent lamps en
dc.subject harmonic analysis en
dc.subject harmonic distortion en
dc.subject photovoltaic power systems en
dc.subject power quality en
dc.subject.classification Engineering, Electrical & Electronic en
dc.subject.other Electric current measurement en
dc.subject.other Electric distortion en
dc.subject.other Electric loads en
dc.subject.other Electric network synthesis en
dc.subject.other Electric power utilization en
dc.subject.other Energy conservation en
dc.subject.other Harmonic analysis en
dc.subject.other Harmonic distortion en
dc.subject.other Installation en
dc.subject.other Photovoltaic effects en
dc.subject.other Transmission network calculations en
dc.subject.other Voltage measurement en
dc.subject.other Compact fluorescent lamps (CFL) en
dc.subject.other Energy saving lamps en
dc.subject.other Harmonic currents en
dc.subject.other Line voltage distortion en
dc.subject.other Photovoltaic power systems en
dc.subject.other Photovoltaic station en
dc.subject.other Power quality en
dc.subject.other Fluorescent lamps en
dc.title Influence of large-scale installation of energy saving lamps on the line voltage distortion of a weak network supplied by photovoltaic station en
heal.type journalArticle en
heal.identifier.primary 10.1109/TPWRD.2004.835432 en
heal.identifier.secondary http://dx.doi.org/10.1109/TPWRD.2004.835432 en
heal.language English en
heal.publicationDate 2004 en
heal.abstract The aim of this research is to calculate and analyze the harmonic distortion extent caused in weak low-voltage networks due to a possible large-scale installation of the widely spread compact fluorescent lamps (CFLs). The research uses data from laboratory measurements of the produced harmonic currents by CFLs, as well as field measurements of the harmonic content and other characteristic measurements of the electric network of a small Greek island, which is supplied by an autonomous photovoltaic (PV) station. The PV station is also a harmonic generator by itself. This fact combined with other highly nonlinear loads-such as CFLs-causes serious problems at the network power quality as undesirable harmonic components are induced. The whole network is simulated and three scenarios of CFL installation extent are considered, so that the harmonic flow analysis reveals the influence in the power quality. It is examined whether this weak low-voltage electric network is able to keep the total harmonic distortion factor at all nodes under 8%, as more and more CFLs are installed. The conclusions drawn from this analysis are important and must be taken into account in every electric network design. © 2004 IEEE. en
heal.publisher IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC en
heal.journalName IEEE Transactions on Power Delivery en
dc.identifier.doi 10.1109/TPWRD.2004.835432 en
dc.identifier.isi ISI:000224278600037 en
dc.identifier.volume 19 en
dc.identifier.issue 4 en
dc.identifier.spage 1787 en
dc.identifier.epage 1793 en