dc.contributor.author |
Ochsenkuhn-Petropoulou, MTh |
en |
dc.contributor.author |
Tsopelas, FN |
en |
dc.date.accessioned |
2014-03-01T01:21:22Z |
|
dc.date.available |
2014-03-01T01:21:22Z |
|
dc.date.issued |
2004 |
en |
dc.identifier.issn |
1618-2642 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/16214 |
|
dc.subject |
Ion-exchange separation |
en |
dc.subject |
Organoselenium compounds |
en |
dc.subject |
Selenocystamine |
en |
dc.subject |
Selenourea |
en |
dc.subject |
Urine |
en |
dc.subject |
Voltammetry |
en |
dc.subject.classification |
Biochemical Research Methods |
en |
dc.subject.classification |
Chemistry, Analytical |
en |
dc.subject.other |
Amines |
en |
dc.subject.other |
Ammonium compounds |
en |
dc.subject.other |
Body fluids |
en |
dc.subject.other |
Electrochemical electrodes |
en |
dc.subject.other |
Electrochemistry |
en |
dc.subject.other |
Ethanol |
en |
dc.subject.other |
Hydrochloric acid |
en |
dc.subject.other |
Ion exchange |
en |
dc.subject.other |
Mass spectrometry |
en |
dc.subject.other |
Polypropylenes |
en |
dc.subject.other |
Positive ions |
en |
dc.subject.other |
Selenium compounds |
en |
dc.subject.other |
Separation |
en |
dc.subject.other |
Toxicity |
en |
dc.subject.other |
Urea |
en |
dc.subject.other |
Ion exchange separation |
en |
dc.subject.other |
Organoselenium compounds |
en |
dc.subject.other |
Selenocystamine |
en |
dc.subject.other |
Selenourea |
en |
dc.subject.other |
Urine |
en |
dc.subject.other |
Voltammetry |
en |
dc.subject.other |
Organometallics |
en |
dc.subject.other |
carbon |
en |
dc.subject.other |
cystamine |
en |
dc.subject.other |
drug derivative |
en |
dc.subject.other |
electrolyte |
en |
dc.subject.other |
organoselenium derivative |
en |
dc.subject.other |
selenocystamine |
en |
dc.subject.other |
selenourea |
en |
dc.subject.other |
urea |
en |
dc.subject.other |
adult |
en |
dc.subject.other |
article |
en |
dc.subject.other |
chemistry |
en |
dc.subject.other |
electrochemistry |
en |
dc.subject.other |
fly ash |
en |
dc.subject.other |
human |
en |
dc.subject.other |
isolation and purification |
en |
dc.subject.other |
male |
en |
dc.subject.other |
particulate matter |
en |
dc.subject.other |
sensitivity and specificity |
en |
dc.subject.other |
soil |
en |
dc.subject.other |
time |
en |
dc.subject.other |
urinalysis |
en |
dc.subject.other |
urine |
en |
dc.subject.other |
Adult |
en |
dc.subject.other |
Carbon |
en |
dc.subject.other |
Cystamine |
en |
dc.subject.other |
Electrochemistry |
en |
dc.subject.other |
Electrolytes |
en |
dc.subject.other |
Humans |
en |
dc.subject.other |
Male |
en |
dc.subject.other |
Organoselenium Compounds |
en |
dc.subject.other |
Particulate Matter |
en |
dc.subject.other |
Sensitivity and Specificity |
en |
dc.subject.other |
Soil |
en |
dc.subject.other |
Time Factors |
en |
dc.subject.other |
Urea |
en |
dc.subject.other |
Urinalysis |
en |
dc.subject.other |
Urine |
en |
dc.title |
Separation of organoselenium compounds and their electrochemical detection |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1007/s00216-004-2511-7 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1007/s00216-004-2511-7 |
en |
heal.language |
English |
en |
heal.publicationDate |
2004 |
en |
heal.abstract |
A simplified procedure based on ion-exchange separation of selenourea (Se-U) and selenocystamine (Se-CM), which have very close half-wave potential when they are simultaneously analyzed by voltammetric techniques, has been developed and optimized. Thus, selenocystamine remains in the cation exchanger Purolite C 100 H, whereas selenourea is found in the effluent and is determined by square wave cathodic stripping voltammetry using Na2CO3 as electrolyte. Selenocystamine is then eluted from the cation exchanger using 4 M HCl and analyzed by square wave cathodic stripping voltammetry in the HCl solution. For each voltammetric determination the corresponding parameters were investigated and optimized; the obtained detection limits were 0.3 ng Se mL -1 for Se-CM and 2 ng Se mL-1 for Se-U. A flow sheet for the separation of inorganic (Se(IV) and Se(VI)) and organoselenium compounds (Se-U, Se-CM, (CH3)2Se2, and (CH 3)2Se) developed for their electrochemical detection is presented and it was successfully applied to a certified reference material, an environmental soil sample, and a urine sample. © Springer-Verlag 2004. |
en |
heal.publisher |
SPRINGER HEIDELBERG |
en |
heal.journalName |
Analytical and Bioanalytical Chemistry |
en |
dc.identifier.doi |
10.1007/s00216-004-2511-7 |
en |
dc.identifier.isi |
ISI:000223474200006 |
en |
dc.identifier.volume |
379 |
en |
dc.identifier.issue |
5-6 |
en |
dc.identifier.spage |
770 |
en |
dc.identifier.epage |
776 |
en |