HEAL DSpace

Power control technique for high speed downlink packet access system

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Mousa, A en
dc.date.accessioned 2014-03-01T01:22:58Z
dc.date.available 2014-03-01T01:22:58Z
dc.date.issued 2005 en
dc.identifier.issn 0926-6801 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/16743
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-26444483232&partnerID=40&md5=c86078c4089be73687eb20d2d6cc3901 en
dc.relation.uri http://www.informatik.uni-trier.de/~ley/db/journals/jhsn/jhsn14.html#Mousa05 en
dc.relation.uri http://iospress.metapress.com/openurl.asp?genre=article&issn=0926-6801&volume=14&issue=4&spage=293 en
dc.subject Average power en
dc.subject C/I en
dc.subject Fading en
dc.subject Outage probability en
dc.subject Power Control en
dc.subject.classification Computer Science, Hardware & Architecture en
dc.subject.classification Computer Science, Information Systems en
dc.subject.classification Engineering, Electrical & Electronic en
dc.subject.classification Telecommunications en
dc.subject.other Algorithms en
dc.subject.other Computer simulation en
dc.subject.other Fading (radio) en
dc.subject.other Power control en
dc.subject.other Probability en
dc.subject.other Telecommunication links en
dc.subject.other Wave propagation en
dc.subject.other Average power en
dc.subject.other C/I en
dc.subject.other High speed downlink packet access (HSDPA) en
dc.subject.other Outage probability en
dc.subject.other Packet networks en
dc.title Power control technique for high speed downlink packet access system en
heal.type journalArticle en
heal.language English en
heal.publicationDate 2005 en
heal.abstract In this paper a Power Control technique for the High Speed Downlink Packet Access (HSDPA) system is proposed and compared to the UMTS-standard technique. In addition to compensating the propagation losses (distance-loss, shadowing and fast fading), the proposed technique adapts the signal-to-cochannel interference ratio (C/I) to be in the required range. The power control algorithm uses a predefined C/I threshold (C/I_th) specific for each service and data rate. When the measured C/I of the user equipment is above (lower) than the C/I_th, the decrease (increase) of power is ordered adaptively depending on the difference between the two values. The two techniques were evaluated by simulation in the framework of the project IST-FITNESS (IST-2000-30116, Fourth-generation Intelligent Transparent Networks Enhanced through Space-time Systems), where an effective software platform simulating the HSDPA network was developed. The numerical results quantitatively outline the benefits on system performance, for each technique, achieved in terms of average transmitted power and outage probability of C/I versus velocity. © 2005 - IOS Press and the authors. All rights reserved. en
heal.publisher IOS PRESS en
heal.journalName Journal of High Speed Networks en
dc.identifier.isi ISI:000232504300002 en
dc.identifier.volume 14 en
dc.identifier.issue 4 en
dc.identifier.spage 293 en
dc.identifier.epage 300 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής