HEAL DSpace

A comparative study of numerical models for Eulerian-Lagrangian simulations of turbulent evaporating sprays

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kolaitis, DI en
dc.contributor.author Founti, MA en
dc.date.accessioned 2014-03-01T01:23:22Z
dc.date.available 2014-03-01T01:23:22Z
dc.date.issued 2006 en
dc.identifier.issn 0142-727X en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/16935
dc.subject spray modelling en
dc.subject droplet evaporation en
dc.subject heat and mass transfer en
dc.subject two-phase CFD en
dc.subject.classification Thermodynamics en
dc.subject.classification Engineering, Mechanical en
dc.subject.classification Mechanics en
dc.subject.other PHASE-DOPPLER ANEMOMETRY en
dc.subject.other DROPLET EVAPORATION en
dc.subject.other VARIABLE PROPERTIES en
dc.subject.other FUEL DROPLET en
dc.subject.other MASS-TRANSFER en
dc.subject.other FLOW en
dc.subject.other COMBUSTION en
dc.subject.other VAPORIZATION en
dc.subject.other EXPANSION en
dc.subject.other PREDICTION en
dc.title A comparative study of numerical models for Eulerian-Lagrangian simulations of turbulent evaporating sprays en
heal.type journalArticle en
heal.identifier.primary 10.1016/j.ijheatfluidflow.2006.01.002 en
heal.identifier.secondary http://dx.doi.org/10.1016/j.ijheatfluidflow.2006.01.002 en
heal.language English en
heal.publicationDate 2006 en
heal.abstract The paper comparatively assesses the computational performance of a selected number of theoretical and semi-empirical liquid droplet evaporation models that focus on thermodynamic non-equilibrium effects, physical property estimation methods and convective and blowing effect corrections for the calculation of the heat and mass transfer rates. Three different test cases are examined in order to establish the most appropriate model, in terms of both physical accuracy and numerical efficiency for implementation in two-phase CFD spray simulations. The considered cases span from a single, isolated droplet, evaporating in a convective environment, to a fully turbulent, evaporating, hollow cone spray; for the latter case, an in-house Eulerian-Lagrangian CFD code is used. Predictions are validated against experimental data for all test cases and the most promising model is established on the basis of accuracy and CPU time requirements. As a result, the "infinite conductivity" equilibrium droplet evaporation model, combined with an analytic expression for the convective and blowing effect correction can be proposed as most appropriate for CFD spray applications. (C) 2006 Elsevier Inc. All rights reserved. en
heal.publisher ELSEVIER SCIENCE INC en
heal.journalName INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW en
dc.identifier.doi 10.1016/j.ijheatfluidflow.2006.01.002 en
dc.identifier.isi ISI:000237638400006 en
dc.identifier.volume 27 en
dc.identifier.issue 3 en
dc.identifier.spage 424 en
dc.identifier.epage 435 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής