HEAL DSpace

A technical evaluation framework for the connection of DG to the distribution network

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Papathanassiou, SA en
dc.date.accessioned 2014-03-01T01:25:51Z
dc.date.available 2014-03-01T01:25:51Z
dc.date.issued 2007 en
dc.identifier.issn 0378-7796 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/17769
dc.subject Distributed generation (DG) en
dc.subject Distribution networks en
dc.subject Flicker en
dc.subject Harmonics en
dc.subject Interconnection en
dc.subject Power quality en
dc.subject Protection en
dc.subject Voltage variations en
dc.subject.classification Engineering, Electrical & Electronic en
dc.subject.other Electric potential en
dc.subject.other Electric power system protection en
dc.subject.other Electric utilities en
dc.subject.other Flickering en
dc.subject.other Distributed generation (DG) en
dc.subject.other Flicker en
dc.subject.other Harmonics en
dc.subject.other Interconnection en
dc.subject.other Power quality en
dc.subject.other Voltage variations en
dc.subject.other Electric power distribution en
dc.title A technical evaluation framework for the connection of DG to the distribution network en
heal.type journalArticle en
heal.identifier.primary 10.1016/j.epsr.2006.01.009 en
heal.identifier.secondary http://dx.doi.org/10.1016/j.epsr.2006.01.009 en
heal.language English en
heal.publicationDate 2007 en
heal.abstract Technical advances and institutional changes in the electric power industry have resulted in a constantly increasing penetration of distributed generation (DG) resources in the grids. For the connection of new DG installations to the network a variety of factors are taken into account, including technical requirements imposed by utilities to ensure that the DG station does not adversely affect the operation and safety of the network. In this paper, fundamental issues related to the interconnection of DG installations to the grid are discussed and evaluation rules are presented, which address power quality considerations and are suitable for application by electric utility and DG engineers. The attention is focused on the steady-state and fast voltage variations, flicker and harmonic emissions. The simplified evaluation procedures of the paper are largely based on the relevant IEC publications and reflect the current practice of several European utilities. A discussion of the interconnection protection requirements is also included in the paper. (C) 2006 Elsevier B.V. All rights reserved. en
heal.publisher ELSEVIER SCIENCE SA en
heal.journalName Electric Power Systems Research en
dc.identifier.doi 10.1016/j.epsr.2006.01.009 en
dc.identifier.isi ISI:000240907500003 en
dc.identifier.volume 77 en
dc.identifier.issue 1 en
dc.identifier.spage 24 en
dc.identifier.epage 34 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής