HEAL DSpace

Evaluation of thermal comfort in Galatsi Arena of the Olympics ""Athens 2004"" using a CFD model

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Stamou, AI en
dc.contributor.author Katsiris, I en
dc.contributor.author Schaelin, A en
dc.date.accessioned 2014-03-01T01:28:21Z
dc.date.available 2014-03-01T01:28:21Z
dc.date.issued 2008 en
dc.identifier.issn 1359-4311 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/18810
dc.subject Computational fluid dynamics (CFD) en
dc.subject Indoor stadiums en
dc.subject Mathematical models en
dc.subject Thermal comfort en
dc.subject.classification Thermodynamics en
dc.subject.classification Energy & Fuels en
dc.subject.classification Engineering, Mechanical en
dc.subject.classification Mechanics en
dc.subject.other Gymnasiums en
dc.subject.other Mathematical models en
dc.subject.other Stadiums en
dc.subject.other Temperature distribution en
dc.subject.other Conditioned inlet air en
dc.subject.other Predicted percentage of dissatisfied (PPD) en
dc.subject.other Table tennis en
dc.subject.other Thermal comfort en
dc.title Evaluation of thermal comfort in Galatsi Arena of the Olympics ""Athens 2004"" using a CFD model en
heal.type journalArticle en
heal.identifier.primary 10.1016/j.applthermaleng.2007.07.020 en
heal.identifier.secondary http://dx.doi.org/10.1016/j.applthermaleng.2007.07.020 en
heal.language English en
heal.publicationDate 2008 en
heal.abstract A computational fluid dynamics (CFD) model was used to evaluate the thermal comfort conditions in the indoor stadium of the Galatsi Arena, which hosted the sports of rhythmic gymnastics and table tennis during the Olympic Games "Athens 2004". The CFD code CFX was applied to calculate the 3D airflow and temperature fields in the Arena for various values of temperatures (T-in) of conditioned inlet air. Calculated mean velocities and temperatures were used to determine the thermal comfort indices predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD) and to evaluate the thermal conditions in the various regions of the Arena. Calculated PMV and PPD values showed that thermal conditions in the Galatsi Arena were very satisfactory for T-in = 16 degrees C; only a small percentage (<7%) of the spectators was expected to be slightly uncomfortable. (C) 2007 Elsevier Ltd. All rights reserved. en
heal.publisher PERGAMON-ELSEVIER SCIENCE LTD en
heal.journalName Applied Thermal Engineering en
dc.identifier.doi 10.1016/j.applthermaleng.2007.07.020 en
dc.identifier.isi ISI:000256202900011 en
dc.identifier.volume 28 en
dc.identifier.issue 10 en
dc.identifier.spage 1206 en
dc.identifier.epage 1215 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής