dc.contributor.author |
Loizos, G |
en |
dc.contributor.author |
Kefalas, T |
en |
dc.contributor.author |
Kladas, A |
en |
dc.contributor.author |
Souflaris, T |
en |
dc.contributor.author |
Paparigas, D |
en |
dc.date.accessioned |
2014-03-01T01:28:24Z |
|
dc.date.available |
2014-03-01T01:28:24Z |
|
dc.date.issued |
2008 |
en |
dc.identifier.issn |
0304-8853 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/18847 |
|
dc.subject |
Magnetic flux distribution |
en |
dc.subject |
Transformer |
en |
dc.subject |
Wound core |
en |
dc.subject.classification |
Materials Science, Multidisciplinary |
en |
dc.subject.classification |
Physics, Condensed Matter |
en |
dc.subject.other |
Magnetic circuits |
en |
dc.subject.other |
Numerical methods |
en |
dc.subject.other |
Elsevier (CO) |
en |
dc.subject.other |
Experimental results |
en |
dc.subject.other |
Flux densities |
en |
dc.subject.other |
flux density distribution |
en |
dc.subject.other |
Flux distributions |
en |
dc.subject.other |
Harmonics content |
en |
dc.subject.other |
Lap joints |
en |
dc.subject.other |
Magnetic (CE) |
en |
dc.subject.other |
Magnetic behaviors |
en |
dc.subject.other |
Numerical modelling |
en |
dc.subject.other |
Single phasing |
en |
dc.subject.other |
transformer cores |
en |
dc.subject.other |
Variations of |
en |
dc.subject.other |
Iron |
en |
dc.title |
Flux distribution in single phase, Si-Fe, wound transformer cores |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1016/j.jmmm.2008.04.068 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1016/j.jmmm.2008.04.068 |
en |
heal.language |
English |
en |
heal.publicationDate |
2008 |
en |
heal.abstract |
This paper shows experimental results of longitudinal flux density and its harmonics at the limb, the yoke and the corner as well as normal flux in the step lap joint of a single phase, Si-Fe, wound transformer core. Results show that the flux density as well as the harmonics content is higher in the inner (window) side of the core and reduces gradually towards the outer side. Variations of flux density distribution between the limb and the corner or the yoke of the core were observed. A full record of normal flux around the step lap region of the model core was also obtained. Longitudinal and normal flux findings will enable the development of more accurate numerical models that describe the magnetic behavior of magnetic cores. (C) 2008 Elsevier B.V. All rights reserved. |
en |
heal.publisher |
ELSEVIER SCIENCE BV |
en |
heal.journalName |
Journal of Magnetism and Magnetic Materials |
en |
dc.identifier.doi |
10.1016/j.jmmm.2008.04.068 |
en |
dc.identifier.isi |
ISI:000257950700109 |
en |
dc.identifier.volume |
320 |
en |
dc.identifier.issue |
20 |
en |
dc.identifier.spage |
e874 |
en |
dc.identifier.epage |
e877 |
en |