dc.contributor.author |
Efstathopoulos, N |
en |
dc.contributor.author |
Nikolaou, VS |
en |
dc.contributor.author |
Xypnitos, FN |
en |
dc.contributor.author |
Korres, D |
en |
dc.contributor.author |
Lazarettos, I |
en |
dc.contributor.author |
Panousis, K |
en |
dc.contributor.author |
Kasselouris, EN |
en |
dc.contributor.author |
Venetsanos, DT |
en |
dc.contributor.author |
Provatidis, CG |
en |
dc.date.accessioned |
2014-03-01T01:33:40Z |
|
dc.date.available |
2014-03-01T01:33:40Z |
|
dc.date.issued |
2010 |
en |
dc.identifier.issn |
0020-1383 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/20526 |
|
dc.subject |
Intramedullary nail |
en |
dc.subject |
Distal screw |
en |
dc.subject |
Finitive element method |
en |
dc.subject |
Fi-nail |
en |
dc.subject |
Biomechanical behaviour |
en |
dc.subject.classification |
Critical Care Medicine |
en |
dc.subject.classification |
Emergency Medicine |
en |
dc.subject.classification |
Orthopedics |
en |
dc.subject.classification |
Surgery |
en |
dc.subject.other |
DYNAMIC HIP SCREW |
en |
dc.subject.other |
PROXIMAL FEMORAL NAIL |
en |
dc.subject.other |
GAMMA-NAIL |
en |
dc.subject.other |
INTERTROCHANTERIC FRACTURES |
en |
dc.subject.other |
PERITROCHANTERIC FRACTURES |
en |
dc.subject.other |
SUBTROCHANTERIC FRACTURES |
en |
dc.subject.other |
INTERNAL-FIXATION |
en |
dc.subject.other |
CONTROLLED TRIAL |
en |
dc.subject.other |
FEMUR |
en |
dc.subject.other |
PLATE |
en |
dc.title |
Investigation on the distal screw of a trochanteric intramedullary implant (Fi-nail) using a simplified finite element model |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1016/j.injury.2009.09.006 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1016/j.injury.2009.09.006 |
en |
heal.language |
English |
en |
heal.publicationDate |
2010 |
en |
heal.abstract |
Numerous studies have been published conceit-ling the characteristics and the behaviour of the intramedullary devices in the treatment of the intertrochanteric hip fractures However, there is still room for further exploration and exploitation concerning the implant behaviour with respect to the par is of the implant assembly (nail, lag screw and distal screw) Towards this direction, the present paper armed at revealing the effect of the position of the distal screw on the mechanical behaviour of the fixation device For this purpose, a simplified model was developed and analysed with the finite element method In total, five different locations for the distal screw were examined In all cases, the bone was fixed at its distal end while the external load was applied at the tip of the lag screw towards the hip and in the form of orthonormal force components applied individually The results of the FE analyses were illustrated in appropriately formed plots revealing the sensitivity of the behaviour of the implant with respect to the location of the distal screw The main conclusion derived from the present investigation was that moving the distal screw apically decreases the stresses on the distal screw but increases the stresses on the lag screw In turn, this Indicates the existence of a location for the distal spew that compromises these two effects in an optimum way (C) 2009 Elsevier Ltd All rights reserved |
en |
heal.publisher |
ELSEVIER SCI LTD |
en |
heal.journalName |
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED |
en |
dc.identifier.doi |
10.1016/j.injury.2009.09.006 |
en |
dc.identifier.isi |
ISI:000276155600004 |
en |
dc.identifier.volume |
41 |
en |
dc.identifier.issue |
3 |
en |
dc.identifier.spage |
259 |
en |
dc.identifier.epage |
265 |
en |