dc.contributor.author |
Karfopoulos, KL |
en |
dc.contributor.author |
Anagnostakis, MJ |
en |
dc.date.accessioned |
2014-03-01T01:34:04Z |
|
dc.date.available |
2014-03-01T01:34:04Z |
|
dc.date.issued |
2010 |
en |
dc.identifier.issn |
0969-8043 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/20670 |
|
dc.subject |
Detector efficiency |
en |
dc.subject |
Gamma spectrometry |
en |
dc.subject |
Monte Carlo simulation |
en |
dc.subject.classification |
Chemistry, Inorganic & Nuclear |
en |
dc.subject.classification |
Nuclear Science & Technology |
en |
dc.subject.classification |
Radiology, Nuclear Medicine & Medical Imaging |
en |
dc.subject.other |
Detector efficiency |
en |
dc.subject.other |
Full energy peak |
en |
dc.subject.other |
Gamma spectrometry |
en |
dc.subject.other |
HPGe detectors |
en |
dc.subject.other |
Monte Carlo Simulation |
en |
dc.subject.other |
PENELOPE |
en |
dc.subject.other |
Simulation parameters |
en |
dc.subject.other |
Computer simulation |
en |
dc.subject.other |
Cosmic ray detectors |
en |
dc.subject.other |
Detectors |
en |
dc.subject.other |
Gamma ray spectrometers |
en |
dc.subject.other |
Spectrometry |
en |
dc.subject.other |
Monte Carlo methods |
en |
dc.subject.other |
accuracy |
en |
dc.subject.other |
article |
en |
dc.subject.other |
calculation |
en |
dc.subject.other |
compton effect |
en |
dc.subject.other |
computer analysis |
en |
dc.subject.other |
computer simulation |
en |
dc.subject.other |
controlled study |
en |
dc.subject.other |
energy recovery |
en |
dc.subject.other |
energy transfer |
en |
dc.subject.other |
gamma radiation |
en |
dc.subject.other |
gamma spectrometry |
en |
dc.subject.other |
mathematical computing |
en |
dc.subject.other |
Monte Carlo method |
en |
dc.subject.other |
particle size |
en |
dc.subject.other |
photon |
en |
dc.subject.other |
priority journal |
en |
dc.subject.other |
probability |
en |
dc.subject.other |
process model |
en |
dc.subject.other |
radiation detection |
en |
dc.subject.other |
standard |
en |
dc.subject.other |
X ray |
en |
dc.title |
Parameters affecting full energy peak efficiency determination during Monte Carlo simulation |
en |
heal.type |
journalArticle |
en |
heal.identifier.primary |
10.1016/j.apradiso.2009.11.020 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1016/j.apradiso.2009.11.020 |
en |
heal.language |
English |
en |
heal.publicationDate |
2010 |
en |
heal.abstract |
Aim of this work is to study the effect of various simulation parameters on the calculation of the full energy peak efficiency of HPGe detectors with the Monte Carlo simulation code PENELOPE. (C) 2009 Elsevier Ltd All rights reserved. |
en |
heal.publisher |
PERGAMON-ELSEVIER SCIENCE LTD |
en |
heal.journalName |
Applied Radiation and Isotopes |
en |
dc.identifier.doi |
10.1016/j.apradiso.2009.11.020 |
en |
dc.identifier.isi |
ISI:000279123900051 |
en |
dc.identifier.volume |
68 |
en |
dc.identifier.issue |
7-8 |
en |
dc.identifier.spage |
1435 |
en |
dc.identifier.epage |
1437 |
en |