HEAL DSpace

Parameters affecting full energy peak efficiency determination during Monte Carlo simulation

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Karfopoulos, KL en
dc.contributor.author Anagnostakis, MJ en
dc.date.accessioned 2014-03-01T01:34:04Z
dc.date.available 2014-03-01T01:34:04Z
dc.date.issued 2010 en
dc.identifier.issn 0969-8043 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/20670
dc.subject Detector efficiency en
dc.subject Gamma spectrometry en
dc.subject Monte Carlo simulation en
dc.subject.classification Chemistry, Inorganic & Nuclear en
dc.subject.classification Nuclear Science & Technology en
dc.subject.classification Radiology, Nuclear Medicine & Medical Imaging en
dc.subject.other Detector efficiency en
dc.subject.other Full energy peak en
dc.subject.other Gamma spectrometry en
dc.subject.other HPGe detectors en
dc.subject.other Monte Carlo Simulation en
dc.subject.other PENELOPE en
dc.subject.other Simulation parameters en
dc.subject.other Computer simulation en
dc.subject.other Cosmic ray detectors en
dc.subject.other Detectors en
dc.subject.other Gamma ray spectrometers en
dc.subject.other Spectrometry en
dc.subject.other Monte Carlo methods en
dc.subject.other accuracy en
dc.subject.other article en
dc.subject.other calculation en
dc.subject.other compton effect en
dc.subject.other computer analysis en
dc.subject.other computer simulation en
dc.subject.other controlled study en
dc.subject.other energy recovery en
dc.subject.other energy transfer en
dc.subject.other gamma radiation en
dc.subject.other gamma spectrometry en
dc.subject.other mathematical computing en
dc.subject.other Monte Carlo method en
dc.subject.other particle size en
dc.subject.other photon en
dc.subject.other priority journal en
dc.subject.other probability en
dc.subject.other process model en
dc.subject.other radiation detection en
dc.subject.other standard en
dc.subject.other X ray en
dc.title Parameters affecting full energy peak efficiency determination during Monte Carlo simulation en
heal.type journalArticle en
heal.identifier.primary 10.1016/j.apradiso.2009.11.020 en
heal.identifier.secondary http://dx.doi.org/10.1016/j.apradiso.2009.11.020 en
heal.language English en
heal.publicationDate 2010 en
heal.abstract Aim of this work is to study the effect of various simulation parameters on the calculation of the full energy peak efficiency of HPGe detectors with the Monte Carlo simulation code PENELOPE. (C) 2009 Elsevier Ltd All rights reserved. en
heal.publisher PERGAMON-ELSEVIER SCIENCE LTD en
heal.journalName Applied Radiation and Isotopes en
dc.identifier.doi 10.1016/j.apradiso.2009.11.020 en
dc.identifier.isi ISI:000279123900051 en
dc.identifier.volume 68 en
dc.identifier.issue 7-8 en
dc.identifier.spage 1435 en
dc.identifier.epage 1437 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής