HEAL DSpace

Optimal design of single-phase shell-type distribution transformers based on a multiple design method validated by measurements

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Olivares-Galvan, JC en
dc.contributor.author Georgilakis, PS en
dc.contributor.author Escarela-Perez, R en
dc.contributor.author Campero-Littlewood, E en
dc.date.accessioned 2014-03-01T01:36:35Z
dc.date.available 2014-03-01T01:36:35Z
dc.date.issued 2011 en
dc.identifier.issn 0948-7921 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/21347
dc.subject Conductor selection en
dc.subject Design en
dc.subject Design optimization en
dc.subject Distribution en
dc.subject Excitation current en
dc.subject Transformer en
dc.subject.classification Engineering, Electrical & Electronic en
dc.subject.other Conductor selection en
dc.subject.other Design optimization en
dc.subject.other Distribution en
dc.subject.other Excitation current en
dc.subject.other Transformer en
dc.subject.other Algorithms en
dc.subject.other Electric transformers en
dc.subject.other Manufacture en
dc.subject.other Nameplates en
dc.subject.other Optimization en
dc.subject.other Design en
dc.title Optimal design of single-phase shell-type distribution transformers based on a multiple design method validated by measurements en
heal.type journalArticle en
heal.identifier.primary 10.1007/s00202-011-0211-9 en
heal.identifier.secondary http://dx.doi.org/10.1007/s00202-011-0211-9 en
heal.language English en
heal.publicationDate 2011 en
heal.abstract This paper presents a method for the design of shell-type, single-phase distribution transformers to obtain the manufacturing specifications. The method is simple, efficient and accurate. By an exhaustive analysis, it is concluded that the obtained solution is the global optimum. The following constraints are imposed: excitation current, no-load losses, total losses, impedance and efficiency. The methodology of this paper requires only six input data: transformer rating, low voltage, high voltage, connection of low-voltage coil, connection of high-voltage coil, and frequency. These data are included in the transformer nameplate. In this paper, the minimization of the following four objective functions is considered: total owing cost, mass, total losses and material cost. The consideration of these four objective functions is implemented automatically by running the optimization algorithm four times without intervention of a designer. Consequently, transformer manufacturers save designman-hours and increase capacity. A design example on a 25 kVA transformer is presented for illustration. The optimized solutions of transformer design are validated with laboratory and process measurements. © Springer-Verlag 2011. en
heal.publisher SPRINGER en
heal.journalName Electrical Engineering en
dc.identifier.doi 10.1007/s00202-011-0211-9 en
dc.identifier.isi ISI:000296736700005 en
dc.identifier.volume 93 en
dc.identifier.issue 4 en
dc.identifier.spage 237 en
dc.identifier.epage 246 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής