HEAL DSpace

Time dependence of creep recovery in cross-linked polymers

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Theocaris, PS en
dc.date.accessioned 2014-03-01T01:37:40Z
dc.date.available 2014-03-01T01:37:40Z
dc.date.issued 1967 en
dc.identifier.issn 00354511 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/21617
dc.title Time dependence of creep recovery in cross-linked polymers en
heal.type journalArticle en
heal.identifier.primary 10.1007/BF01976441 en
heal.identifier.secondary http://dx.doi.org/10.1007/BF01976441 en
heal.publicationDate 1967 en
heal.abstract Transient creep recovery tests in simple tension were performed in a series of cross-linked high polymers in pure and plasticized states. A loading cycle was adopted according to which each specimen was loaded in creep for a time period of 16′ followed by recovery for the same time period. This loading cycle was repeated for various steps of temperature from ambient temperature up to a temperature corresponding to the rubbery region of each polymer. It was shown that, while the 15″ measurements of deformation after loading or unloading were approximately equal, recovery individual curves were always lagging in time the corresponding creep curves. Composite curves of creep or recovery deformation in semi-log time scale reduced to a temperature of 30 °C were plotted by applying the method of reduced variables. The creepdeformation composite curve was always advancing in time relatively to the respective recovery composite curve. This phenomenon was an accumulation of the partial difference of the corresponding individual curves. Time-shift factor versus temperature curves for creep and recovery were plotted and compared. It was established that the remaining deformation after 16 minutes of a 16′ creep recovery normalized to the initial deformation at the beginning of recovery, if plotted versus temperature, presented the same shape of curves for all types of materials tested. The maxima of these curves were diminishing with addition of plasticizer according to a straight line. © 1967 Dr. Dietrich Steinkopff Verlag. en
heal.publisher Steinkopff-Verlag en
heal.journalName Rheologica Acta en
dc.identifier.doi 10.1007/BF01976441 en
dc.identifier.volume 6 en
dc.identifier.issue 3 en
dc.identifier.spage 246 en
dc.identifier.epage 251 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής