HEAL DSpace

Simulation of a high voltage measuring system

DSpace/Manakin Repository

Show simple item record

dc.contributor.author Topalis, FV en
dc.date.accessioned 2014-03-01T01:39:25Z
dc.date.available 2014-03-01T01:39:25Z
dc.date.issued 1988 en
dc.identifier.issn 07612508 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/22783
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-0024143899&partnerID=40&md5=2227123a8518d1f37a10f1001328fe7c en
dc.subject.other Computer Simulation--Applications en
dc.subject.other Data Conversion, Analog to Digital--Applications en
dc.subject.other Distributed/Concentrated Elements en
dc.subject.other High Voltage Measuring System en
dc.subject.other Quadripole Simulation en
dc.subject.other Transient Digitizer en
dc.subject.other Electric Measurements en
dc.title Simulation of a high voltage measuring system en
heal.type journalArticle en
heal.publicationDate 1988 en
heal.abstract A method of simulation of a high impulse voltage measuring system is presented in this paper. The response of the system at any excitation can be calculated by means of a computer program which has been developed, based on the proposed method. The measuring system is represented by a chain of distributed and concentrated elements, each one simulated by a quadripole. For a given input voltage the voltage at the output of the system can be evaluated by a step-by-step computation at each quadripole moving from the input towards the output. The input voltage is given either by its analytical expression or by its digital form recorded by means of an A/D converter (transient digitizer). en
heal.journalName Modelling, Measurement and Control A en
dc.identifier.volume 17 en
dc.identifier.issue 3 en
dc.identifier.spage 29 en
dc.identifier.epage 39 en


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record