dc.contributor.author Rogdakis, ED en
dc.date.accessioned 2014-03-01T01:40:46Z
dc.date.available 2014-03-01T01:40:46Z
dc.date.issued 1991 en
dc.identifier.issn 09601481 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/23232
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-0026383637&partnerID=40&md5=4c65ddfd71bf177ce458ba550e0ab14a en
dc.subject.other Mathematical Models en
dc.subject.other Mathematical Techniques--Finite Difference Method en
dc.subject.other Solar Radiation--Collectors en
dc.subject.other Heat Transport Equation en
dc.subject.other Mass Flow Rate en
dc.subject.other Water Heaters en
dc.title A correlation for the optimum collector flow rate in one tank forced circulation solar water heaters en
heal.type journalArticle en
heal.publicationDate 1991 en
heal.abstract A mathematical model has been developed, which simulates the operation of one tank forced circulation solar water heaters, based on a finite-difference solution of the one-dimensional transient heat transport equation by convection and conduction along the prevailing direction of the storage tank. By applying the developed procedure over a wide range of conditions, a large number of predictions has been obtained, which showed that the optimum ratio of collector to mean load mass flow rates (m ̇c/{A figure is presented}1)opt, i.e. that which maximizes the performance of the system, varies from 0.4 to 1.4 and can be expressed as a function of the ratio of the mean load mass flow rate to collector area, {A figure is presented}1/Ac, only. By correlating the numerous predictions obtained, the function (m ̇c/{A figure is presented}1)opt = f({A figure is presented}1/Ac) is developed and presented. The proposed correlation provides a simple and quick way of estimating, with an accuracy which is satisfactory for practical applications, the optimum collector flow rate in one tank forced circulation solar water heaters, using as the only data the mean load mass flow rate and the collector area. © 1991. en
heal.journalName Renewable Energy en
dc.identifier.volume 1 en
dc.identifier.issue 3-4 en
dc.identifier.spage 373 en
dc.identifier.epage 379 en