HEAL DSpace

Upgrading of a T.T.P. mill - application to selective clinker grinding

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Tsivilis, S en
dc.contributor.author Tsimas, S en
dc.contributor.author Kelemanis, L en
dc.contributor.author Parissakis, G en
dc.date.accessioned 2014-03-01T01:42:42Z
dc.date.available 2014-03-01T01:42:42Z
dc.date.issued 1994 en
dc.identifier.issn 02636050 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/23911
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-0028443474&partnerID=40&md5=82ff2d167b7d648cc591a67d9a3c478a en
dc.subject.other Agglomeration en
dc.subject.other Efficiency en
dc.subject.other Equipment testing en
dc.subject.other Grinding (comminution) en
dc.subject.other Particle size analysis en
dc.subject.other Particles (particulate matter) en
dc.subject.other Separation en
dc.subject.other Vibrations (mechanical) en
dc.subject.other Vibrators en
dc.subject.other Clinker grinding en
dc.subject.other Granulometry en
dc.subject.other Laboratory scale grinding device en
dc.subject.other Materials selection en
dc.subject.other Particle size distribution en
dc.subject.other Surface grinding area en
dc.subject.other TTP mills en
dc.subject.other Grinding mills en
dc.title Upgrading of a T.T.P. mill - application to selective clinker grinding en
heal.type journalArticle en
heal.publicationDate 1994 en
heal.abstract This article refers to the operation of an improved model of the T.T.P. (R)mill. This laboratory mill combines selective grinding and, at the same time, separation of pre-ground material. The basic unit of the laboratory-scale grinding device is a mill, with a curved surface grinding area, and a vibrator. During the operation of the unit and due to appropriate vibrational movements the fines are gathered at the edges of the mill, while the coarses remain at the centre. The fines are then transfered to the next grinding stage or delivered as the final product. The machine was tested for clinker grinding with a capacity of 5.7 kg/h (old model 0.3 kg/h). The obtained product indicates a very selective granulometry with 8.5% in the fraction with size less than 3 μm, 69.9% in the size fraction 3-32 μm and specific surface only 2790 cm2/g. en
heal.journalName World Cement en
dc.identifier.volume 25 en
dc.identifier.issue 6 en
dc.identifier.spage 34 en
dc.identifier.epage 36 en