dc.contributor.author | Kakaras, E | en |
dc.date.accessioned | 2014-03-01T01:48:32Z | |
dc.date.available | 2014-03-01T01:48:32Z | |
dc.date.issued | 1999 | en |
dc.identifier.issn | 14353199 | en |
dc.identifier.uri | https://dspace.lib.ntua.gr/xmlui/handle/123456789/25516 | |
dc.relation.uri | http://www.scopus.com/inward/record.url?eid=2-s2.0-0032691173&partnerID=40&md5=786672b651efd43af42ff7fd83c8e870 | en |
dc.subject.other | Coal fired boilers | en |
dc.subject.other | Cooling towers | en |
dc.subject.other | Energy efficiency | en |
dc.subject.other | Feedwater heaters | en |
dc.subject.other | Flue gases | en |
dc.subject.other | Gas emissions | en |
dc.subject.other | Industrial emissions | en |
dc.subject.other | Lignite | en |
dc.subject.other | Retrofitting | en |
dc.subject.other | Soot blowers | en |
dc.subject.other | Steam turbines | en |
dc.subject.other | Lignite-fired power plants | en |
dc.subject.other | Fossil fuel power plants | en |
dc.title | Efficiency improvement of existing lignite-fired power plants | en |
heal.type | journalArticle | en |
heal.publicationDate | 1999 | en |
heal.abstract | In this paper the results of an extended study aiming at the efficiency improvement of Greek lignite-fired power plants are presented. The investigations deal with the evaluation of several measures taken in connection with the boiler refurbishment, such as: - boiler sealing (reduction of leakage air), - optimization of the soot blowers performance, - installation of additional heating surfaces, together with optimization measures for the cold end of the water-steam cycle through modifications of the - steam turbine, - cooling towers. In accordance with the international experience, the results of this study have confirmed that: - the replacement of the turbine blades and the measures for the cold end optimization have a significant effect on the efficiency improvement, - the reduction of the flue gas outlet temperature through the installation of additional heating surfaces mainly results in the performance improvement of the ESP's and additionally it has only a limited influence on the power plant efficiency, - boiler sealing measures for the reduction of the infiltration air and the soot blower measures should be realized in the short run. | en |
heal.journalName | VGB PowerTech | en |
dc.identifier.volume | 79 | en |
dc.identifier.issue | 9 | en |
dc.identifier.spage | 37 | en |
dc.identifier.epage | 43 | en |
Αρχεία | Μέγεθος | Μορφότυπο | Προβολή |
---|---|---|---|
Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο. |