HEAL DSpace

An Experimental Method to Investigate the Optimal UV Filter for the Auger Fluorescence Detectors

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Maltezos, S en
dc.contributor.author Fokitis, E en
dc.date.accessioned 2014-03-01T01:49:08Z
dc.date.available 2014-03-01T01:49:08Z
dc.date.issued 2000 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/25699
dc.subject Background Radiation en
dc.subject Experimental Method en
dc.subject Extensive Air Shower en
dc.subject Light Intensity en
dc.subject Photon Counting en
dc.subject Simulation Software en
dc.subject Fluorescence Detector en
dc.title An Experimental Method to Investigate the Optimal UV Filter for the Auger Fluorescence Detectors en
heal.type journalArticle en
heal.publicationDate 2000 en
heal.abstract A specic experimental method, in order to investigate the more suit- able UV lter to install in the Fluorescence Detector (FD) of the AUGER Project, is presented in this work. A prototype experimental setup has been developed for this purpose. As detector, it uses an elementary cell, similar to the one used in the FD. A fast and sensitive photon en