HEAL DSpace

DVH computation comparisons using conventional methods and optimized FFT algorithms for brachytherapy

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kemmerer, T en
dc.contributor.author Lahanas, M en
dc.contributor.author Baltas, D en
dc.contributor.author Zamboglou, N en
dc.date.accessioned 2014-03-01T01:49:21Z
dc.date.available 2014-03-01T01:49:21Z
dc.date.issued 2000 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/25736
dc.subject Dose Volume Histogram en
dc.subject Fast Fourier Transform en
dc.title DVH computation comparisons using conventional methods and optimized FFT algorithms for brachytherapy en
heal.type journalArticle en
heal.publicationDate 2000 en
heal.abstract In anatomy based optimization procedures for large volume implants the calculationof dose-volume histograms (DVH) accounts for the major part of the time involved and canbe as long as a few hours. This time is proportional to the number of seeds or source dwellpositions required for the implant. A procedure for the calculation of brachytherapy seeddose distribution calculation employing fast Fourier en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής