HEAL DSpace

Characteristics of DuPont photopolymers for slanted holographic grating formations

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Wu, S-D en
dc.contributor.author Glytsis, EN en
dc.date.accessioned 2014-03-01T01:53:39Z
dc.date.available 2014-03-01T01:53:39Z
dc.date.issued 2004 en
dc.identifier.issn 07403224 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/27090
dc.subject.other Angle measurement en
dc.subject.other Diffraction gratings en
dc.subject.other Diffusion en
dc.subject.other Holographic optical elements en
dc.subject.other Holography en
dc.subject.other Light modulation en
dc.subject.other Light transmission en
dc.subject.other Mathematical models en
dc.subject.other Optimization en
dc.subject.other Polyethylene terephthalates en
dc.subject.other Refractive index en
dc.subject.other Shrinkage en
dc.subject.other Anagular selectivity measurement en
dc.subject.other Coupled wave analysis en
dc.subject.other Holographic grating formations en
dc.subject.other Photopolymers en
dc.subject.other Real time diffraction en
dc.subject.other Refractive index modulation en
dc.subject.other Optical films en
dc.title Characteristics of DuPont photopolymers for slanted holographic grating formations en
heal.type journalArticle en
heal.identifier.primary 10.1364/JOSAB.21.001722 en
heal.identifier.secondary http://dx.doi.org/10.1364/JOSAB.21.001722 en
heal.publicationDate 2004 en
heal.abstract The characteristic parameters of DuPont OmniDex613 photopolymers including the shrinkage factor, diffusion coefficient, and nonlocal response length are studied for slanted holographic gratings recorded at the UV wavelength of 363.8 nm by application of the rigorous coupled-wave analysis in conjunction with an angular-selectivity measurement, a real-time diffraction-monitoring technique, and a nonlocal diffusion model. Both small (<20 deg) and large (>40 deg) slant-angle gratings are presented. Depending on the exposure intensity, the recording shrinkage factor of the photopolymer varies from ∼2.75% to ∼4.20%. Furthermore, the effects of postbaking conditions on the refractive-index modulations and the shifts of Bragg angles for slanted holographic gratings are also investigated systematically. It is found that the postbaking processing can not only increase the refractive-index modulations from Δn1 ∼ 0.013 to ∼0.028 for a small slant-angle grating and from Δn1 ∼ 0.011 to ∼0.022 for a large slant-angle grating, but can also compensate the recording shrinkage. © 2004 Optical Society of America. en
heal.journalName Journal of the Optical Society of America B: Optical Physics en
dc.identifier.doi 10.1364/JOSAB.21.001722 en
dc.identifier.volume 21 en
dc.identifier.issue 10 en
dc.identifier.spage 1722 en
dc.identifier.epage 1731 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής