HEAL DSpace

Correlation of transiently evoked otoacoustic emission measures to auditory thresholds

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Balatsouras, DG en
dc.contributor.author Kaberos, A en
dc.contributor.author Karapantzos, I en
dc.contributor.author Homsioglou, E en
dc.contributor.author Economou, NC en
dc.contributor.author Korres, S en
dc.date.accessioned 2014-03-01T01:53:56Z
dc.date.available 2014-03-01T01:53:56Z
dc.date.issued 2004 en
dc.identifier.issn 1234-1010 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/27139
dc.subject transiently evoked otoacoustic emissions en
dc.subject auditory threshold en
dc.subject hearing en
dc.subject regression analysis en
dc.subject.classification Medicine, Research & Experimental en
dc.subject.other NORMAL-HEARING en
dc.title Correlation of transiently evoked otoacoustic emission measures to auditory thresholds en
heal.type journalArticle en
heal.language English en
heal.publicationDate 2004 en
heal.abstract Background: The presence of otoacoustic emissions is objective evidence of normal cochlear status. However, this test cannot be used to predict absolute auditory thresholds with accuracy. The criteria of normal otoacoustic emissions are not yet standardized and different measures of otoacoustic emissions have been used in various settings. In this study, the measures of reproducibility and otoacoustic emission amplitude are compared with regard to their correlation to pure-tone auditory (PTA) thresholds. Material/Methods: One hundred and seventeen subjects with normal hearing were included in the study. Subjects with previous audiological, otolaryngologic, or vestibular disease were excluded. A complete ENT and audiological work-up was performed, including transiently evoked otoacoustic emissions (TEOAEs). The equipment used for TEOAE testing was a DP Echoport ILO 292 Otodynamics analyzer connected to a portable personal computer. A full 260 low-noise samples were averaged. Results: Correlation between PTA thresholds and either overall TEOAE amplitude or whole reproducibility was estimated using multiple regression analysis. Correlation between acoustic thresholds at 250, 500, 1000, 2000, 4000 and 8000 Hz and either whole reproducibility or emission amplitude was highly significant for both measures. However, whole reproducibility was better correlated to acoustic thresholds at 250, 500, 1000, 2000, 4000 and 8000 Hz than was emission amplitude, and was more accurately predicted from multiple regression equations. Conclusions: Reproducibility measures performed better than TEOAE amplitude levels in the prediction of auditory thresholds. en
heal.publisher INT SCIENTIFIC LITERATURE, INC en
heal.journalName MEDICAL SCIENCE MONITOR en
dc.identifier.isi ISI:000224831400020 en
dc.identifier.volume 10 en
dc.identifier.issue 2 en
dc.identifier.spage MT24 en
dc.identifier.epage MT30 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)