HEAL DSpace

Error evaluation of integral methods by consideration on the approximation of temperature integral

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Liu, N en
dc.contributor.author Chen, H en
dc.contributor.author Shu, L en
dc.contributor.author Statheropoulos, M en
dc.date.accessioned 2014-03-01T01:54:35Z
dc.date.available 2014-03-01T01:54:35Z
dc.date.issued 2005 en
dc.identifier.issn 1388-6150 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/27440
dc.subject error evaluation en
dc.subject kinetic analysis en
dc.subject temperature integral en
dc.subject.classification Chemistry, Analytical en
dc.subject.classification Chemistry, Physical en
dc.subject.other ISOTHERMAL KINETIC-PARAMETERS en
dc.subject.other NONISOTHERMAL REACTIONS en
dc.subject.other THERMAL-DECOMPOSITION en
dc.subject.other TGA DATA en
dc.subject.other FORMULA en
dc.subject.other INTERVALS en
dc.title Error evaluation of integral methods by consideration on the approximation of temperature integral en
heal.type journalArticle en
heal.language English en
heal.publicationDate 2005 en
heal.abstract In this paper, the integral methods in general use are divided into two types in terms of their different ways to in order to deal with the temperature integral p(x): for Type A the function h(x)=p(x)x(2)e(x) is regarded as constant vs. x, while for Type B h(x) varies vs. x and ln[p(x)] is assumed to have the approximation form of ln[p(x)]=alnx+bx+c (the coefficients a, b, and c are constant). The errors of kinetic parameters calculated by these two types of methods are derived as functions of x and analyzed theoretically. It is found that Type A methods have the common errors of activation energy, while the Coats-Redfern method can lead to more accurate value of frequency factor than others. The accuracy of frequency factor can be further enhanced by adjusting the expression of the Coats-Redfern approximation. Although using quite simple approximation of the temperature integral, the Coats-Redfern method has the best performance among Type A methods, implying that usage of a sophisticated approximation may be unnecessary in kinetic analysis. For Type B, the revised MKN method has a lower error in activation energy and an acceptable error in frequency factor, and thus it can be reliably used. Comparatively, the Doyle method has higher error of activation energy and great error of the frequency factor, and thus it is not recommended to be adopted in kinetic analysis. en
heal.publisher SPRINGER en
heal.journalName JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY en
dc.identifier.isi ISI:000230263500016 en
dc.identifier.volume 81 en
dc.identifier.issue 1 en
dc.identifier.spage 99 en
dc.identifier.epage 105 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής