dc.contributor.author | Maglaras, A | en |
dc.contributor.author | Maglara, S | en |
dc.date.accessioned | 2014-03-01T01:55:29Z | |
dc.date.available | 2014-03-01T01:55:29Z | |
dc.date.issued | 2006 | en |
dc.identifier.issn | 11092777 | en |
dc.identifier.uri | https://dspace.lib.ntua.gr/xmlui/handle/123456789/27758 | |
dc.relation.uri | http://www.scopus.com/inward/record.url?eid=2-s2.0-33744764018&partnerID=40&md5=8db4dd2654ba61ab17378c22ebcc0d70 | en |
dc.subject | Air gaps | en |
dc.subject | Corona | en |
dc.subject | FEM | en |
dc.subject | Field strength | en |
dc.subject | Ground effect | en |
dc.subject | Polarity effect | en |
dc.subject | Simulation | en |
dc.subject.other | Electric breakdown | en |
dc.subject.other | Electric corona | en |
dc.subject.other | Energy gap | en |
dc.subject.other | Finite element method | en |
dc.subject.other | Ground effect | en |
dc.subject.other | Polarization | en |
dc.subject.other | Corona effects | en |
dc.subject.other | Polarity effects | en |
dc.subject.other | Rod-plate air gaps | en |
dc.subject.other | Electrodes | en |
dc.title | The ground effect in small rod-plate air gaps in connection to the corona effects and the polarity effect | en |
heal.type | journalArticle | en |
heal.publicationDate | 2006 | en |
heal.abstract | In the present paper the Ground Effect of small rod-plate air gaps, which is observed due to the grounding of one of the electrodes, is investigated. Values of the field strength in the gap are recorded and analyzed for the two different arrangements, with the rod or the plate grounded. The distribution of the field along the axis of the gap is strongly affected by the geometry of the gap, the magnitude of the surrounding, the density of the mesh, and especially by the electrode chosen to be grounded. The Ground Effect also affects the breakdown voltage of the rod-plate air gaps but in a quite different way than the Polarity Effect does. The values of the breakdown voltage depend on the maximum value of the field strength in the gap, as well as the corona leakage current through the gap. According to the Polarity Effect the breakdown voltage is considerably higher in the arrangement with negative polarity on the rod because of the intensive corona effects. According to the Ground Effect the breakdown voltage is higher in the arrangement with the rod grounded because the maximum value of the field strength is lower. The Ground Effect is intense in small rod-plate air gaps, while the influence of the corona leakage current and the Polarity Effect appears in longer air gaps. | en |
heal.journalName | WSEAS Transactions on Systems | en |
dc.identifier.volume | 5 | en |
dc.identifier.issue | 5 | en |
dc.identifier.spage | 1021 | en |
dc.identifier.epage | 1028 | en |