HEAL DSpace

Hydrothermal scheduling of power system with stochastic inflows

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kavatza, SD en
dc.contributor.author Contaxis, GC en
dc.date.accessioned 2014-03-01T02:40:55Z
dc.date.available 2014-03-01T02:40:55Z
dc.date.issued 1989 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/30274
dc.subject Case Study en
dc.subject Constrained Optimization Problem en
dc.subject Optimal Method en
dc.subject Power System en
dc.subject Scheduling Problem en
dc.subject.other Electric Power Plants--Hydroelectric and Steam Combined en
dc.subject.other Probability en
dc.subject.other Hydrothermal Scheduling en
dc.subject.other Optimum Hydro Energy Allocation en
dc.subject.other Stochastic Inflows en
dc.subject.other Suboptimal Optimization Method en
dc.subject.other Thermal Units Dispatch en
dc.subject.other Electric Power Systems en
dc.title Hydrothermal scheduling of power system with stochastic inflows en
heal.type conferenceItem en
heal.identifier.primary 10.1109/MELCON.1989.49988 en
heal.identifier.secondary http://dx.doi.org/10.1109/MELCON.1989.49988 en
heal.publicationDate 1989 en
heal.abstract The authors present a suboptimal optimization method for solving the annual hydrothermal scheduling problem. Hydrothermal scheduling is performed in order to find the optimum allocation of hydro energy so that the annual operating cost of a mixed hydro-thermal system is minimized. In the present work the hydrothermal scheduling problem is decomposed into three subproblems: maintenance of thermal units, dispatch of thermal units, and dispatch of hydro units. The algorithm takes into consideration the stochastic nature of the water inflows to the reservoir and the forced outage rates of the thermal units. Maintenance scheduling is performed based on the levelized risk criterion, dispatch of the thermal units is determined based on probabilistic techniques, while the dispatch of the hydro units is formulated as a constrained optimization problem. Results obtained by the application of the algorithm to a case study showing the effect of the hydro units are reported. en
heal.publisher Publ by IEEE, Piscataway, NJ, United States en
heal.journalName [No source information available] en
dc.identifier.doi 10.1109/MELCON.1989.49988 en
dc.identifier.spage 87 en
dc.identifier.epage 90 en


Αρχεία σε αυτό το τεκμήριο