HEAL DSpace

Computation of heart electric current sources based on a general inverse technique and measurement of the skin potentials

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Michael, Christian en
dc.contributor.author Papaodysseus, Kostas en
dc.contributor.author Uzunoglu, Nikolaos en
dc.date.accessioned 2014-03-01T02:41:11Z
dc.date.available 2014-03-01T02:41:11Z
dc.date.issued 1996 en
dc.identifier.issn 05891019 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/30410
dc.subject Computational Techniques en
dc.subject Electrostatic Potential en
dc.subject Finite Difference en
dc.subject Generalized Inverse en
dc.subject Optimal Algorithm en
dc.subject Surface Potential en
dc.subject Three Dimensional en
dc.subject.other Algorithms en
dc.subject.other Bioelectric potentials en
dc.subject.other Cardiology en
dc.subject.other Computerized tomography en
dc.subject.other Electroencephalography en
dc.subject.other Electromyography en
dc.subject.other Finite difference method en
dc.subject.other Medical computing en
dc.subject.other Medical imaging en
dc.subject.other Skin en
dc.subject.other Tissue en
dc.subject.other Heart electric current sources en
dc.subject.other Inversion algorithm en
dc.subject.other Electrocardiography en
dc.title Computation of heart electric current sources based on a general inverse technique and measurement of the skin potentials en
heal.type conferenceItem en
heal.identifier.primary 10.1109/IEMBS.1996.647482 en
heal.identifier.secondary http://dx.doi.org/10.1109/IEMBS.1996.647482 en
heal.publicationDate 1996 en
heal.abstract A three dimensional computational technique of heart electrical sources is developed by measuring related surface potentials at 64 points and using inverse techniques to compute the myocardium current sources. The inversion algorithm is based on the use of a finite difference solution technique of the corresponding electrostatic potential problem and an optimization algorithm to find the 'best inverse solution'. A prototype clinical system has been developed and the inversion algorithm has been embedded into this. en
heal.publisher IEEE, Piscataway, NJ, United States en
heal.journalName Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings en
dc.identifier.doi 10.1109/IEMBS.1996.647482 en
dc.identifier.volume 4 en
dc.identifier.spage 1415 en
dc.identifier.epage 1416 en