dc.contributor.author |
Karagiannopoulos, CG |
en |
dc.contributor.author |
Agoris, DP |
en |
dc.contributor.author |
Psomopoulos, CS |
en |
dc.contributor.author |
Bourkas, PD |
en |
dc.date.accessioned |
2014-03-01T02:41:37Z |
|
dc.date.available |
2014-03-01T02:41:37Z |
|
dc.date.issued |
1999 |
en |
dc.identifier.issn |
00849162 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/30563 |
|
dc.subject |
a/d converter |
en |
dc.subject |
Electric Field |
en |
dc.subject |
Electrical Properties |
en |
dc.subject |
Negative Differential Resistance |
en |
dc.subject |
Partial Discharge |
en |
dc.subject |
Sampling Frequency |
en |
dc.subject |
Analog Digital Converter |
en |
dc.subject.other |
Dielectric materials |
en |
dc.subject.other |
Electric breakdown of solids |
en |
dc.subject.other |
Electric currents |
en |
dc.subject.other |
Electric field effects |
en |
dc.subject.other |
Electric potential |
en |
dc.subject.other |
Electric resistance |
en |
dc.subject.other |
Partial discharges |
en |
dc.subject.other |
Impulse voltage |
en |
dc.subject.other |
Negative differential resistance |
en |
dc.subject.other |
Electric insulating materials |
en |
dc.title |
Partial discharges in solid insulators - an experimental investigation |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1109/CEIDP.1999.804624 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1109/CEIDP.1999.804624 |
en |
heal.publicationDate |
1999 |
en |
heal.abstract |
The application of strong electric fields reaching breakdown values, on industrial dielectrics has a profound effect on their electrical properties. Partial discharges are among the parameters of primary importance, which affect the aging procedure. In this paper a measuring method is proposed which involves high sampling frequency analog/digital converters to the classical experimental set up. Focusing in a single partial discharge, the individual characteristics i.e. the energy of electrons and the emitted radiation, are reported. This was achieved as HSF A/D converters provides a considerable number of measurements of the potential profile across a measuring capacitor (or resistance) even in the sort time period of a single partial discharge. From the results it may be stated that s-type negative differential resistance and current instabilities during the prebreakdown stages of industrial insulators are presented. |
en |
heal.publisher |
IEEE, Piscataway, NJ, United States |
en |
heal.journalName |
Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report |
en |
dc.identifier.doi |
10.1109/CEIDP.1999.804624 |
en |
dc.identifier.volume |
1 |
en |
dc.identifier.spage |
193 |
en |
dc.identifier.epage |
196 |
en |