dc.title |
Unstable frequency oscillations in a slow-response reheat-turbine generator |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1109/PESW.1999.747439 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1109/PESW.1999.747439 |
en |
heal.publicationDate |
1999 |
en |
heal.abstract |
This paper shows that governor rate limits may result in slow response that interacts with that of a reheat turbine to create unstable frequency oscillations. The origin of these oscillations is explained with a linear analogue, while nonlinear simulation shows that the oscillations evolve into a limit cycle due to gate limits. A control scheme to stabilize the frequency oscillations through control of the intercept valve is developed and tested in the paper. |