HEAL DSpace

Identification of synchronous machine parameters using constrained optimization

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Hatziargyriou, ND en
dc.contributor.author Karapidakis, ES en
dc.contributor.author Stavrakakis, GS en
dc.contributor.author Dimopoulos, IF en
dc.contributor.author Kalaitzakis, K en
dc.date.accessioned 2014-03-01T02:41:53Z
dc.date.available 2014-03-01T02:41:53Z
dc.date.issued 2001 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/30658
dc.subject Dynamic models en
dc.subject Isolated power system en
dc.subject Parameters identification en
dc.subject System simulation en
dc.subject.other Estimated parameter en
dc.subject.other Isolated power system en
dc.subject.other Operational conditions en
dc.subject.other Parameters identification en
dc.subject.other Power variations en
dc.subject.other Real measurements en
dc.subject.other Simulation model en
dc.subject.other Synchronous machine en
dc.subject.other System dynamic models en
dc.subject.other System simulations en
dc.subject.other Transient performance en
dc.subject.other Unknown parameters en
dc.subject.other Computer simulation en
dc.subject.other Constrained optimization en
dc.subject.other Dynamic models en
dc.subject.other Identification (control systems) en
dc.subject.other Synchronous machinery en
dc.subject.other Parameter estimation en
dc.title Identification of synchronous machine parameters using constrained optimization en
heal.type conferenceItem en
heal.identifier.primary 10.1109/PTC.2001.964812 en
heal.identifier.secondary http://dx.doi.org/10.1109/PTC.2001.964812 en
heal.identifier.secondary 964812 en
heal.publicationDate 2001 en
heal.abstract In order to investigate transient performance problems in isolated power systems an accurate system dynamic model is required. Real measurements, under specific system operational conditions, have been used for the identification of the conventional generator unknown parameters. Frequency and power variations, resulting from the simulation model using the estimated parameters, are compared with the frequency and power deviations, measured during the corresponding real operational conditions in order to demonstrate the successful performance of the proposed methodology. © 2001 IEEE. en
heal.journalName 2001 IEEE Porto Power Tech Proceedings en
dc.identifier.doi 10.1109/PTC.2001.964812 en
dc.identifier.volume 4 en
dc.identifier.spage 84 en
dc.identifier.epage 88 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής