HEAL DSpace

Measurement of the monitored drift tubes response to energetic neutrons

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Savva, PS en
dc.contributor.author Alexopoulos, T en
dc.contributor.author Avramidou, R en
dc.contributor.author Dris, M en
dc.contributor.author Fassouliotis, D en
dc.contributor.author Filippas, A en
dc.contributor.author Gazis, EN en
dc.contributor.author Kalfas, K en
dc.contributor.author Katsoufis, E en
dc.contributor.author Kokkoris, M en
dc.contributor.author Kossionidis, E en
dc.contributor.author Maltezos, S en
dc.contributor.author Perdikakis, G en
dc.contributor.author Polychronakos, V en
dc.contributor.author Stavropoulos, G en
dc.contributor.author Tsipolitis, G en
dc.contributor.author Tzamarioudaki, E en
dc.date.accessioned 2014-03-01T02:42:17Z
dc.date.available 2014-03-01T02:42:17Z
dc.date.issued 2003 en
dc.identifier.issn 10957863 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/30910
dc.subject Data Acquisition System en
dc.subject Data Analysis en
dc.subject Scientific Research en
dc.subject.other Computational methods en
dc.subject.other Data acquisition en
dc.subject.other Electric potential en
dc.subject.other High energy physics en
dc.subject.other Neutrons en
dc.subject.other Radiation en
dc.subject.other Sensitivity analysis en
dc.subject.other Energetic neutrons en
dc.subject.other Large hadron collider (LHC) en
dc.subject.other Monitored drift tubes (MDT) en
dc.subject.other Proton proton collisions en
dc.subject.other Drift chambers en
dc.title Measurement of the monitored drift tubes response to energetic neutrons en
heal.type conferenceItem en
heal.identifier.primary 10.1109/NSSMIC.2003.1352658 en
heal.identifier.secondary http://dx.doi.org/10.1109/NSSMIC.2003.1352658 en
heal.identifier.secondary R8-43 en
heal.publicationDate 2003 en
heal.abstract We have measured the response of an array of Monitored Drift Tubes (MDT) to fast neutrons produced by a t(d,n)4He reaction at the TANDEM Van de Graaff accelerator of the National Center of Scientific Research (NCSR) ""Demokritos"". The MDT setup consisted of 24 drift tubes operating with a gas mixture of ArCO2 (93:7%) at 3 bar absolute pressure. The neutron energy was 18.3 MeV. The operating anode wire voltage varied from 2200 V to 2800 V. The PC based data acquisition system was self-triggered by the OR of all 24 MDT. Data were also taken by triggering on a single tube. The data analysis is presented and the response of the MDT detector to energetic neutrons is discussed with emphasis on the determination of the MDT sensitivity to neutrons. en
heal.journalName IEEE Nuclear Science Symposium Conference Record en
dc.identifier.doi 10.1109/NSSMIC.2003.1352658 en
dc.identifier.volume 5 en
dc.identifier.spage 3464 en
dc.identifier.epage 3467 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής