HEAL DSpace

A high-precision X-ray tomograph for quality control of the ATLAS Muon Monitored Drift Tube Chambers

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Schuh, S en
dc.contributor.author Avramidou, R en
dc.contributor.author Banhidi, Z en
dc.contributor.author Fabjan, CW en
dc.contributor.author Lampl, W en
dc.contributor.author Marchesotti, M en
dc.contributor.author Rangod, S en
dc.contributor.author Sbrissa, E en
dc.contributor.author Smirnov, Y en
dc.contributor.author Voss, R en
dc.contributor.author Woudstra, M en
dc.contributor.author Zhuravlov, V en
dc.date.accessioned 2014-03-01T02:42:24Z
dc.date.available 2014-03-01T02:42:24Z
dc.date.issued 2004 en
dc.identifier.issn 01689002 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/30983
dc.subject Driftchambers en
dc.subject Quality control en
dc.subject Tomography en
dc.subject.other Calibration en
dc.subject.other Interferometers en
dc.subject.other Phosphors en
dc.subject.other Photomultipliers en
dc.subject.other Quality control en
dc.subject.other Sampling en
dc.subject.other Tomography en
dc.subject.other Wire en
dc.subject.other X ray analysis en
dc.subject.other X rays en
dc.subject.other Drift tubes en
dc.subject.other Muon spectrometers en
dc.subject.other Drift chambers en
dc.title A high-precision X-ray tomograph for quality control of the ATLAS Muon Monitored Drift Tube Chambers en
heal.type conferenceItem en
heal.identifier.primary 10.1016/j.nima.2003.10.027 en
heal.identifier.secondary http://dx.doi.org/10.1016/j.nima.2003.10.027 en
heal.publicationDate 2004 en
heal.abstract A dedicated X-ray tomograph has been developed at CERN to control the required wire placement accuracy of better than 20μm of the 1200 Monitored Drift Tube Chambers which make up most of the precision chamber part of the ATLAS Muon Spectrometer. The tomograph allows the chamber wire positions to be measured with a 2μm statistical and 2μm systematic uncertainty over the full chamber cross-section of 2.2×0.6m2. Consistent chamber production quality over the 4-year construction phase is ensured with a ∼15% sampling rate. Measurements of about 70 of the 650 MDT chambers so far produced have been essential in assessing the validity and consistency of the various construction procedures. © 2003 Elsevier B.V. All rights reserved. en
heal.journalName Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment en
dc.identifier.doi 10.1016/j.nima.2003.10.027 en
dc.identifier.volume 518 en
dc.identifier.issue 1-2 en
dc.identifier.spage 73 en
dc.identifier.epage 75 en