dc.contributor.author |
Loudos, GK |
en |
dc.contributor.author |
Giokaris, ND |
en |
dc.contributor.author |
Mainta, K |
en |
dc.contributor.author |
Sakelios, N |
en |
dc.contributor.author |
Stiliaris, E |
en |
dc.contributor.author |
Karabarbounis, A |
en |
dc.contributor.author |
Papanicolas, CN |
en |
dc.contributor.author |
Spanoudaki, V |
en |
dc.contributor.author |
Nikita, KS |
en |
dc.contributor.author |
Uzunoglu, NK |
en |
dc.contributor.author |
Archimandritis, SC |
en |
dc.contributor.author |
Varvarigou, AD |
en |
dc.contributor.author |
Stefanis, KN |
en |
dc.contributor.author |
Majewski, S |
en |
dc.contributor.author |
Weisenberger, A |
en |
dc.contributor.author |
Pani, R |
en |
dc.contributor.author |
Maintas, D |
en |
dc.date.accessioned |
2014-03-01T02:42:48Z |
|
dc.date.available |
2014-03-01T02:42:48Z |
|
dc.date.issued |
2004 |
en |
dc.identifier.issn |
0168-9002 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/31085 |
|
dc.subject |
γ-Camera |
en |
dc.subject |
Breast phantom |
en |
dc.subject |
High-resolution |
en |
dc.subject |
PSPMT |
en |
dc.subject |
SPECT |
en |
dc.subject.classification |
Instruments & Instrumentation |
en |
dc.subject.classification |
Nuclear Science & Technology |
en |
dc.subject.classification |
Physics, Particles & Fields |
en |
dc.subject.classification |
Spectroscopy |
en |
dc.subject.other |
Biological organs |
en |
dc.subject.other |
Cameras |
en |
dc.subject.other |
Cost effectiveness |
en |
dc.subject.other |
Gamma rays |
en |
dc.subject.other |
Photomultipliers |
en |
dc.subject.other |
Photons |
en |
dc.subject.other |
Technetium |
en |
dc.subject.other |
Tumors |
en |
dc.subject.other |
γ-camera |
en |
dc.subject.other |
Breast phantom |
en |
dc.subject.other |
High resolution |
en |
dc.subject.other |
PSPMT |
en |
dc.subject.other |
SPECT |
en |
dc.subject.other |
Medical imaging |
en |
dc.title |
High-resolution and high-sensitivity SPECT imaging of breast phantoms |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1016/j.nima.2004.03.083 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1016/j.nima.2004.03.083 |
en |
heal.language |
English |
en |
heal.publicationDate |
2004 |
en |
heal.abstract |
A small field of view gamma camera based on a Position Sensitive Photomultiplier Tube has been used for tomoscintigraphic imaging of breast phantoms. The breast phantoms consist of small hot quantities of Tc-99m placed in a plastic pot filled with a lower concentration Tc-99m solution. The volume of the hot quantities varied from 0.5 to 0.25 ml and the target to background activity ratio varied from 3:1 to 5:1. The impact of the acquisition time per projection and the number of projections on image quality has been investigated. (C) 2004 Elsevier B.V. All rights reserved. |
en |
heal.publisher |
ELSEVIER SCIENCE BV |
en |
heal.journalName |
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
en |
dc.identifier.doi |
10.1016/j.nima.2004.03.083 |
en |
dc.identifier.isi |
ISI:000222712200021 |
en |
dc.identifier.volume |
527 |
en |
dc.identifier.issue |
1-2 |
en |
dc.identifier.spage |
97 |
en |
dc.identifier.epage |
101 |
en |